2007
DOI: 10.1590/s0103-50532007000100025
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of a new samarium(III) ion-selective electrode based on 3-{[2-oxo-1(2h)-acenaphthylenyliden]amino}-2-thioxo -1,3-thiazolidin-4-one

Abstract: Este trabalho apresenta o desenvolvimento de um eletrôdo de membrana de PVC, que contém 3-{[2-oxo-1(2H)-acenonaftilideno]amino}-2-tioxido-1,3-tiazolidino-4-ona (ATTO), que mostrou ser seletivo para íons Sm 3+. Os dados obtidos mostram uma resposta Nernsteniana com inclinação de 19,3 ± 0,6 mV por década para íons Sm 3+ em uma ampla faixa de concentração , de 1,0 × 10. O limite de detecção encontrado foi (5,5± 0.3) × 10 -7 mol L -1 numa faixa de pH entre 3,5 e 7,5, com tempo de resposta pequeno (~10 s). O sensor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2007
2007
2013
2013

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 56 publications
(17 citation statements)
references
References 47 publications
0
17
0
Order By: Relevance
“…Thus, a quick, convenient, fast method is required to monitor neodymium in large number of environmental samples. Recently many papers for lanthanide ions have been reported La [12][13][14], Ce [15][16][17][18][19][20][21], Pr [22], Sm [23], Tb [24], Ho [25] and Yb [26] ions.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, a quick, convenient, fast method is required to monitor neodymium in large number of environmental samples. Recently many papers for lanthanide ions have been reported La [12][13][14], Ce [15][16][17][18][19][20][21], Pr [22], Sm [23], Tb [24], Ho [25] and Yb [26] ions.…”
Section: Introductionmentioning
confidence: 99%
“…In this work, the selectivity coefficients were determined with the aid of the matched potential method (MPM). [59][60][61][62][63][64][65][66][67] According to this method, the specified activity (concentration) of the primary ions (A = 5 × 10 −5 M) is added to a reference solution (1.0 × 10 −5 M of AgNO 3 ), and the potential is measured. In a separate experiment, the interfering ions (B = 1 × 10 −5 to 1.0 × 0 −1 M) are successively added to an identical reference solution, until the measured potential matches that obtained before the addition of the primary ions.…”
Section: The Sensor Selectivitymentioning
confidence: 99%
“…The tube was, then, removed from the mixture, kept at room temperature for about 24 h and filled with an internal filling solution (1.0 · 10 -3 M of HoCl 3 ). Finally, the electrode was conditioned by soaking in a 1.0 · 10 -2 M HoCl 3 solution for 36 h [19][20][21][22][23][24][25][26][27][28]. As an internal reference electrode, a silver-silver chloride wire was used.…”
Section: Electrode Preparationmentioning
confidence: 99%