2013
DOI: 10.1121/1.4812274
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication and performance of a single-crystal lead magnesium niobate-lead titanate cylindrical hydrophone

Abstract: The development of a piezoelectric hydrophone based on lead magnesium niobate-lead titanate [PbMg1/3Nb2/3O3-PbTiO3 (PMN-PT)] single-crystal piezoelectric as the hydrophone substrate is reported. Although PMN-PT can possess much higher piezoelectric sensitivity than traditional lead zirconate titanate (PZT) piezoelectrics, it is highly anisotropic and therefore there is a large gain in sensitivity only when the crystal structure is oriented in a specific direction. Because of this, simply replacing the PZT subs… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 19 publications
(20 reference statements)
0
8
0
Order By: Relevance
“…The relative improvement in charge sensitivity, voltage sensitivity, and figure of merit (FOM) of the PMN-PT based hydrophone was ~9.1 dB, ~3.5 dB, and 6.3 dB higher than those of the PZT-5A hydrophone, respectively. The size of the PMN-PT hydrophone can be reduced by half of the PZT-5A hydrophone due to its high sensitivity [74]. This result showed a promising point that a certain combination between various crystal cut orientation and suitable design for the sensing mode can improve the performance or reduce the size of hydrophones.…”
Section: Cylinder Hydrophonementioning
confidence: 85%
See 3 more Smart Citations
“…The relative improvement in charge sensitivity, voltage sensitivity, and figure of merit (FOM) of the PMN-PT based hydrophone was ~9.1 dB, ~3.5 dB, and 6.3 dB higher than those of the PZT-5A hydrophone, respectively. The size of the PMN-PT hydrophone can be reduced by half of the PZT-5A hydrophone due to its high sensitivity [74]. This result showed a promising point that a certain combination between various crystal cut orientation and suitable design for the sensing mode can improve the performance or reduce the size of hydrophones.…”
Section: Cylinder Hydrophonementioning
confidence: 85%
“…For underwater detection, the towed array sonar system (TASS) composed of small piezoelectric hydrophones in linear arrangement have become popular [74]. Although the development of fast and versatile signal processing algorithms is important to improve the performance of hydrophone systems, stable pressure sensing with high sensitivity by hydrophone elements is the most important factor for underwater applications [75].…”
Section: Hydrophone Materialsmentioning
confidence: 99%
See 2 more Smart Citations
“…Stretchable speakers use silicon substrates and ionic conductors to produce audible sound [11]. Cylindrical speakers create omnidirectional sound by using PZT tubes [12] or arrays of transducers placed on cylindrical surfaces [1,24].…”
Section: Related Workmentioning
confidence: 99%