2014 Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM) 2014
DOI: 10.1109/semi-therm.2014.6892218
|View full text |Cite
|
Sign up to set email alerts
|

Extracting TIM properties with localized transient pulses

Abstract: Thermal engineers require accurate package-level resistance estimates to design optimized cooling systems. Although Theta-JC is a commonly quoted metric to define the junction to case resistance, it does not accurately predict package performance for a range of heat sink and thermal interface material (TIM) conditions. To overcome this limitation, a steady-state and a transient test method is presented to extract the thermal resistance of the TIM. A high resistance adhesive, a low resistance gel and an Indium … Show more