Exploring the Biomechanical Properties of the Human Cornea In Vivo Based on Corvis ST

Abstract: Purpose: The aim of this study was to provide a method to determine corneal nonlinear viscoelastic properties based on the output data of corneal visualization Scheimpflug technology (Corvis ST).Methods: The Corvis ST data from 18 eyes of 12 healthy humans were collected. Based on the air-puff pressure and the corneal displacement from the Corvis ST test of normal human eyes, the work done by the air-puff attaining the whole corneal displacement was obtained. By applying a visco-hyperelastic strain energy dens… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 46 publications
0
4
0
Order By: Relevance
“…A video clip containing 140 digital frames corresponded to a recording time of 33 msec. The details of measurements on the Corvis ST are described elsewhere ( Robert et al, 2019 ; Zhang et al, 2021a ). In the latest release of the software, more DCR parameters [MIR, DARM (1 mm), DARM (2 mm) PS, ARtH, IR, SP-A1, and CBI) were introduced, together with bIOP.…”
Section: Methodsmentioning
confidence: 99%
“…A video clip containing 140 digital frames corresponded to a recording time of 33 msec. The details of measurements on the Corvis ST are described elsewhere ( Robert et al, 2019 ; Zhang et al, 2021a ). In the latest release of the software, more DCR parameters [MIR, DARM (1 mm), DARM (2 mm) PS, ARtH, IR, SP-A1, and CBI) were introduced, together with bIOP.…”
Section: Methodsmentioning
confidence: 99%
“…However, if we aim to know the characteristics of corneal biomechanical properties of each group, we need to further analysis biomechanical parameters, such as, elastic modulus and nonlinear elasticity, based on the relationship between DCR parameters and corneal biomechanical properties (not established yet) or the established mechanical models using the data output by Corvis ST (Boszczyk et al, 2017;Jannesari et al, 2019;Qin et al, 2019;Zhang et al, 2021), or direct measuring by optical correlation elastic imaging (Singh et al, 2018;Zhou et al, 2019;De Stefano et al, 2020;Chong and Dupps, 2021;Lan et al, 2021), Brillouin microscopy (Yun and Chernyak, 2018;Shao and Eltony, 2019;Chong and Dupps, 2021). In this study, we did not consider the viscous processes and a plastic deformation of the stroma during the surgical procedure.…”
Section: Discussionmentioning
confidence: 99%
“…A method to segment the clinical images of Corvis ST (a commercial NCT) is outlined and a function to approximate the movement of the corneal anterior section is proposed based on the function in [4]. A 2D axisymmetric CFD simulation is conducted with a moving boundary describing the movement of the cornea segmented from the images (Fig.…”
Section: D Cfd Analysis and Iop Estimationmentioning
confidence: 99%