1997
DOI: 10.1080/03067319708028366
|View full text |Cite
|
Sign up to set email alerts
|

Exploration of a Multicapillary Column for Use in Elevated Speed Gas Chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

1999
1999
2021
2021

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 39 publications
(11 citation statements)
references
References 26 publications
0
11
0
Order By: Relevance
“…Suitable columns for IMS are the so called Multi-capillary columns (MCC), which were created at what is now known as the Institute for Ap-plied Physics and the Institute of Catalysis, both in Novosibirsk, Russia, 25,26 and commercialized by the companies SIBERTECH (Novosibirsk, Russia) and ALLTECH (U.S.). The columns consist of a capillary bundle of over 1000 individual capillaries with inner diameters of 43 m. Measurements to characterize these columns performed previously 27 show that the number of theoretical plates per column was high enough (5000 per meter) to merit further evaluation. The sizes of these columns, up to 30 cm for rodshaped columns and up to 100 cm for spiral columns and 3 mm in bundle diameter with potential high volumetric flows are advantageous for portable instruments that perform best at elevated flow rates, such as those necessary for IMS operation.…”
Section: Introductionmentioning
confidence: 99%
“…Suitable columns for IMS are the so called Multi-capillary columns (MCC), which were created at what is now known as the Institute for Ap-plied Physics and the Institute of Catalysis, both in Novosibirsk, Russia, 25,26 and commercialized by the companies SIBERTECH (Novosibirsk, Russia) and ALLTECH (U.S.). The columns consist of a capillary bundle of over 1000 individual capillaries with inner diameters of 43 m. Measurements to characterize these columns performed previously 27 show that the number of theoretical plates per column was high enough (5000 per meter) to merit further evaluation. The sizes of these columns, up to 30 cm for rodshaped columns and up to 100 cm for spiral columns and 3 mm in bundle diameter with potential high volumetric flows are advantageous for portable instruments that perform best at elevated flow rates, such as those necessary for IMS operation.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, a multicapillary (MC) column (a bundle of 919 40-μm capillaries) became commercially available (Alltech, Deerfield, IL) in the form of a 1-m helix . The MC column was shown to preserve the advantages of both packed and capillary columns while eliminating their drawbacks , and turned out to be an attractive tool for GC analysis of organohalogen compounds ,, and for time-resolved introduction of organometallic compounds in atomic spectrometry. Baseline separations could be achieved within a fraction (one-tenth) of the time required in capillary GC. They were reached in the isothermal mode that allowed some reduction of the oven size and increased the sample throughput.…”
mentioning
confidence: 99%
“…For MCCs, which are composed of a large number of parallel glass capillaries (~1000), nonpolar OV-5 (5% diphenyl, 95% dimethylpolysiloxane) was used [ 78 , 99 ]. Compared to the ordinary CC, MCCs allow the separation to be carried out at an elevated speed and can be operated at increased carrier gas flows, which may pose an advantage for IMS analysis [ 100 ]. However, Garrido-Delgado and coworkers obtained the better predictive accuracy for the classification ( k NN classifier with k = 3) between different qualities of olive oil (EVOO, OO, and LVOO), when CC-IMS (83%) versus MCC-IMS (79%) was employed for the separation of the VOCs [ 32 ].…”
Section: Nts-workflowmentioning
confidence: 99%