1999
DOI: 10.1021/ac990525d
|View full text |Cite
|
Sign up to set email alerts
|

Species-Selective Analysis by Microcolumn Multicapillary Gas Chromatography with Inductively Coupled Plasma Mass Spectrometric Detection

Abstract: A glass rod (5-20 cm long, 2 mm o.d.) containing more than 1200 parallel microchannels (< 40 microns i.d.) was converted into a high-resolution (> 100 theoretical plates cm-1) GC column by coating the inside of each channel in a way that compensated for the dispersion of the channel inner diameter. The columns were evaluated for the separation of mixtures of several organometallic (Hg, Sn, Pb) compounds prior to on-line sensitive metalselective detection by ICPMS. Chromatographic separation conditions were opt… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
30
0

Year Published

2001
2001
2020
2020

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(31 citation statements)
references
References 16 publications
(33 reference statements)
1
30
0
Order By: Relevance
“…Coupling of multicapillary GC to ICP-MS as detector for elemental speciation has been demonstrated by Lobinski's group [10].…”
Section: Instrumentationmentioning
confidence: 99%
“…Coupling of multicapillary GC to ICP-MS as detector for elemental speciation has been demonstrated by Lobinski's group [10].…”
Section: Instrumentationmentioning
confidence: 99%
“…In this sense the detection limits achievable by use of GC are much lower than those obtained by HPLC [4], because introduction of the sample to the atomizer is almost 100% efficient. The couplings preferred so far are GC-AAS, GC-MIP-AES, GC-FPD, GC-MS, and, more recently, GC-ICP-MS [5,6,7]. This latest hyphenated technique can furnish detection limits as low as 0.05-0.1 ng mL -1 , as tin [8] -even lower when special preconcentration procedures such as HS-SPME (headspace solid-phase micro extraction) [9] or LVI (largevolume injection) [10] are used.…”
Section: Introductionmentioning
confidence: 99%
“…A detailed description of the pre-commercial interface version has been published. 199,200 A different GC-ICP-MS coupling principle, based on the simultaneous introduction of GC effluent and liquid from a standard spray chamber has been commercialised by Thermo Electron Corp. Here, the GC is coupled to the ICP-MS via a flexible line, using a modified torch, where GC and standard liquid sample introduction are connected simultaneously (Figure 7.13).…”
Section: (B) Commercial Gc-icp-ms Systemsmentioning
confidence: 99%
“…Because of the high costs for the enriched isotope starting material, microscale synthesis methods have been developed. The synthesis and purification of 201 MeHg as well as 199 MeHg has been successfully accomplished using methylation via methylcobalamine. 291,292 Ruiz-Encinar 293 described the synthesis of 118 Sn-labelled DBT as well as the synthesis of a mixed spike containing 119 Sn-labelled MBT, DBT and TBT.…”
Section: (A) Synthesis and Characterisation Of Isotopically Labelled mentioning
confidence: 99%