2018
DOI: 10.1016/j.nima.2018.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Experimental validation of the brightness distribution on the surfaces of coupled and decoupled moderators composed of 99.8% parahydrogen at the J-PARC pulsed spallation neutron source

Abstract:  Users may download and print one copy of any publication from the public portal for the purpose of private study or research.  You may not further distribute the material or use it for any profit-making activity or commercial gain  You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 43 publications
1
4
0
Order By: Relevance
“…A similar figure was calculated for the coupled parahydrogen volume moderator at J-PARC [18]. This non-uniform brightness distribution has been experimentally confirmed by a brightness map measurement of the J-PARC coupled moderator [19]. Our calculations show that the effect is much less pronounced for the 3 cm moderator, and almost cancelled for the 1.5 cm one.…”
Section: Physics Effects 231 Parahydrogensupporting
confidence: 84%
See 1 more Smart Citation
“…A similar figure was calculated for the coupled parahydrogen volume moderator at J-PARC [18]. This non-uniform brightness distribution has been experimentally confirmed by a brightness map measurement of the J-PARC coupled moderator [19]. Our calculations show that the effect is much less pronounced for the 3 cm moderator, and almost cancelled for the 1.5 cm one.…”
Section: Physics Effects 231 Parahydrogensupporting
confidence: 84%
“…Figure19. Relative change in thermal and cold brightness as a function of the premoderator radius, for two configurations, in which the ring outside the premoderator (with inner radius equal to the premoderator radius, and outer radius of 60 cm) is void, or beryllium with 30 vol% water.…”
mentioning
confidence: 99%
“…11b ranges from about 1 to 5.5 Å, and the peak is around 2.5 Å. The apparent valley points on the spectrum curve correspond to the reference values of aluminum main Bragg edges [32], which are originated from the neutron interaction with the detector shell, more precisely, the 0.5-mmthick aluminum window. The detected positions of Bragg edges are almost the same as the standard ones, which demonstrates the correctness and the high precision of the TOF measurement.…”
Section: Resultsmentioning
confidence: 90%
“…These results were almost in accordance with those in refs. [24,25]. This demonstrates that the detector could flexibly adjust the FOV and spatial resolution, and can be used for the Bragg edge imaging.…”
Section: Jinst 19 P01015mentioning
confidence: 86%