2019
DOI: 10.1016/j.cryogenics.2018.12.007
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on the condensation characteristics of nitrogen with non-condensable gas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…However, the influence of the gas phase composition on an oil, gas, and water three-phase composite flow has not been clarified in current relevant studies. In addition to the phase state, flue gas also has a great impact on the dryness of steam, which has attracted the attention of many scholars in recent years [37,38]. Although studies on flue gas-assisted steam development for heavy oil have been conducted for many years, most of the attention has been focused on the oil enhancement mechanism of flue gas to improve recovery, and few discussions have been conducted on the characteristics of steam seepage under the action of flue gas.…”
Section: Introductionmentioning
confidence: 99%
“…However, the influence of the gas phase composition on an oil, gas, and water three-phase composite flow has not been clarified in current relevant studies. In addition to the phase state, flue gas also has a great impact on the dryness of steam, which has attracted the attention of many scholars in recent years [37,38]. Although studies on flue gas-assisted steam development for heavy oil have been conducted for many years, most of the attention has been focused on the oil enhancement mechanism of flue gas to improve recovery, and few discussions have been conducted on the characteristics of steam seepage under the action of flue gas.…”
Section: Introductionmentioning
confidence: 99%
“…Besides, the phenomenon of turbulence in pipe flow caused by boundary condition on pipe-wall and also appears confluence of two flows and the influence of flow velocity [5][6][7][8][9][10][11][12]. The pressure on the backflow flow is very high, and it will cause nitrogen gas leading to standby equipment being condensate [13][14][15][16]. In addition to the condensation of nitrogen gas, nitrogen fluid gas provides high pressure to the screw on the compressor to affect the material life of the screw compressor and also can be caused of leakage [17][18][19][20].…”
Section: Introductionmentioning
confidence: 99%