2022
DOI: 10.1016/j.energy.2021.122410
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on control strategies of radiant floor cooling system with direct-ground cooling source and displacement ventilation system: A case study in an office building

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 30 publications
(9 citation statements)
references
References 49 publications
0
9
0
Order By: Relevance
“…(2) Pollutant exposure reduction index Gao and Niu 73 investigated the microenvironment around the human body with and without a personalized ventilation system using a sitting thermal manikin with a realistic human geometry. They introduced a new evaluation index, the pollutant exposure reduction index η PER , which is the percentage of pollutant concentration reduction in indoor air, as defined in equation (2). In their numerical simulation, the pollutant exposure reduction (PER) in the air was 74%, and the exhalation strongly affected the PER when the personalized airflow speed was low…”
Section: Evaluation Indicesmentioning
confidence: 99%
See 1 more Smart Citation
“…(2) Pollutant exposure reduction index Gao and Niu 73 investigated the microenvironment around the human body with and without a personalized ventilation system using a sitting thermal manikin with a realistic human geometry. They introduced a new evaluation index, the pollutant exposure reduction index η PER , which is the percentage of pollutant concentration reduction in indoor air, as defined in equation (2). In their numerical simulation, the pollutant exposure reduction (PER) in the air was 74%, and the exhalation strongly affected the PER when the personalized airflow speed was low…”
Section: Evaluation Indicesmentioning
confidence: 99%
“…Reducing the energy consumption of buildings has therefore become an urgent need for society. 1,2 Traditional heating, ventilation and air conditioning (HVAC) systems of buildings are mostly designed to provide a uniform thermal environment for the whole space. [3][4][5] Conditioning the indoor environment of unoccupied spaces causes unnecessary energy use.…”
Section: Introductionmentioning
confidence: 99%
“…Although some relevant studies have been conducted on the combination of RFC and DV systems, most have focused on indoor thermal comfort. [30][31][32] The research on the pre-dehumidification of this composite system based on CFD modelling is limited. While experimental studies are reliable, they are characterized by the disadvantages of a high consumption of time, manpower and financial resources.…”
Section: Introductionmentioning
confidence: 99%
“…With respect to RFS control strategies for improving indoor comfort and energy efficiency, Ren et al [43] investigated the operational control of radiant floor cooling, considering several factors (including condensation risk [44,45], achieving dynamic optimal control of the radiant cooling system.…”
Section: Introductionmentioning
confidence: 99%