2020
DOI: 10.1007/s10973-020-09569-z
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study of thermal performance and pressure drop on a solar air heater with different orientations of arc-shape rib roughness

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
20
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(20 citation statements)
references
References 33 publications
0
20
0
Order By: Relevance
“…6.6. Arc-shape ribs 45,[55][56][57][58][59][60] are quite similar in working as V-shape ribs and also similar variation in its configurations. Hostile V-shape, arc shaped provides variable and continuous slope to secondary flow and vortices.…”
Section: Discussion and Future Scopementioning
confidence: 99%
See 2 more Smart Citations
“…6.6. Arc-shape ribs 45,[55][56][57][58][59][60] are quite similar in working as V-shape ribs and also similar variation in its configurations. Hostile V-shape, arc shaped provides variable and continuous slope to secondary flow and vortices.…”
Section: Discussion and Future Scopementioning
confidence: 99%
“…Experimental set-up with all components for an outdoor test. Source: reproduced with permission from Sahu et al, 2020 45.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Many engineering applications, such as chemicals production, refrigeration, car production, and solar air heaters, require a high-performance heat exchanger (HE) to efficiently utilize energy sources, so to achieve advantageous heat exchange with a limited cost [1][2][3][4][5][6]. Thus, several technologies have been studied in the last years to increase the rate of heat transfer (HT) from a tube.…”
Section: Introductionmentioning
confidence: 99%
“…It has been noted that the degree of performance improvement is highly influenced by the type of fin and its geometrical parameter's including pitch, height shape, etc. The configuration presenting maximum heat transfer with minimum pressure drop, i.e., higher thermohydraulic performance, is generally preferred [26,27]. Although this approach indicates selection of collector with maximum overall performance, it failed to ensure the uniformity of air temperature across the collector outlet cross section, which is a vital factor for direct applications of solar collector like drying of crops.…”
Section: Introductionmentioning
confidence: 99%