Experimental research on intraocular aqueous flow by PIV method

Abstract: BackgroundAqueous humor flows regularly from posterior chamber to anterior chamber, and this flow much involves intraocular pressure, the eye tissue nutrition and metabolism.PurposeTo visualize and measure the intraocular flow regular pattern of aqueous humor.MethodIntraocular flow in the vitro eyeball is driven to simulate the physiological aqueous humor flow, and the flow field is measured by Particle Image Velocimetry(PIV). Fluorescent particle solution of a certain concentration was infused into the root o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 17 publications
1
3
0
Order By: Relevance
“…essentially interfere with each other due to the disparity between the scales of their velocity and pressure fields. The radial flow does not significantly modify the velocity field of the natural convection, and this convection does not, as assumed by previous studies, alter the IOP [21,31,[43][44][45]. Table 3 and Fig 4 show the post-operative IOP values in the different scenarios.…”
Section: Plos Onesupporting
confidence: 57%
See 1 more Smart Citation
“…essentially interfere with each other due to the disparity between the scales of their velocity and pressure fields. The radial flow does not significantly modify the velocity field of the natural convection, and this convection does not, as assumed by previous studies, alter the IOP [21,31,[43][44][45]. Table 3 and Fig 4 show the post-operative IOP values in the different scenarios.…”
Section: Plos Onesupporting
confidence: 57%
“…Interestingly, the two flows described above do not essentially interfere with each other due to the disparity between the scales of their velocity and pressure fields. The radial flow does not significantly modify the velocity field of the natural convection, and this convection does not, as assumed by previous studies, alter the IOP [ 21 , 31 , 43 45 ].…”
Section: Methodsmentioning
confidence: 51%
“…The flow field in anterior chamber is measured by particle image velocimetry technology. The pivotal device in our study is image velocimetry system, provided by Beijing Institute of Technology, which can be found in Yang et al [20]. …”
Section: Methodsmentioning
confidence: 99%
“…However, in the present study, although we detected a significant decrease in corneal densitometry between post-operative Day 1 and postoperative Month 12, we did not detect any remarkable changes in endothelial cell density. We suggest that changes in corneal densitometry may be caused by various factors, including the density and function of endothelial cells, the balance between the stromal swelling pressure and the endothelial pump rate [31,32], the corneal wound healing reaction and even the quality of tear film [33]. Additional studies are needed to determine the primary cause of a decrease in corneal densitometry.…”