2020
DOI: 10.1016/j.applthermaleng.2019.114855
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation on the influence of internal heat exchanger in a transcritical CO2 heat pump water heater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
13
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 71 publications
(19 citation statements)
references
References 23 publications
2
13
0
1
Order By: Relevance
“…u,CCOP=(((∂CCOP/∂Q,evp)×u,Q,evp) 2 +((∂CCOP/∂P, cmr)×u,P,cmr) 2 ) 0.5 (8) where u,Q,evp is the uncertainty of the ,̇, which was calculated as: u,Q,evp=(((∂Q,evp/∂m,evp)×u,m,evp) 2 +((∂Q,evp/∂T,ev p,i)×u,T,evp,i) 2 +((∂Q,evp/∂T,evp,o)×u,T,evp,o) 2 ) 0.5 (9) where u,m,evp is the uncertainty of the m,evp, u,T,evp,i is the uncertainty of the T,evp,i, and u,T,evp,o is the uncertainty of the T,evp,o.…”
Section: Uncertainty Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…u,CCOP=(((∂CCOP/∂Q,evp)×u,Q,evp) 2 +((∂CCOP/∂P, cmr)×u,P,cmr) 2 ) 0.5 (8) where u,Q,evp is the uncertainty of the ,̇, which was calculated as: u,Q,evp=(((∂Q,evp/∂m,evp)×u,m,evp) 2 +((∂Q,evp/∂T,ev p,i)×u,T,evp,i) 2 +((∂Q,evp/∂T,evp,o)×u,T,evp,o) 2 ) 0.5 (9) where u,m,evp is the uncertainty of the m,evp, u,T,evp,i is the uncertainty of the T,evp,i, and u,T,evp,o is the uncertainty of the T,evp,o.…”
Section: Uncertainty Analysismentioning
confidence: 99%
“…These advantages motivate more studies about the CO2 heat pumps. For instance, an experimental study indicated that the coefficient of performance (COP) of the CO2 heat pump could be improved when the internal heat exchanger was applied [9]. The results presented in the Dai et al's study [10] indicated that the utilization of the direct dedicated mechanical subcooling technology could also improve the COP of the CO2 heat pump.…”
Section: Introductionmentioning
confidence: 99%
“…In the past few years much, scientific attention has been paid to the use of vapor compression cycles with and without internal heat exchangers [2][3][4][5]. Research works have dealt with the comparison of cooling capacity amounts, power consumption of the system and COP parameters when operating at various evaporation and condenser temperatures implementing R1234yf and R1234ze(E) as possible alternatives for R134a [6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…In this type of cycle, only one expansion valve is needed. Among the authors who have studied the cycle with IHX, can be found the works by Lorentzen [32], Nekså et al [35], Liao et al [51], Aprea & Maiorino [52], Chen and Gu [53], Pérez-García et al [54], Minetto et al [42], Shao et al [55] and Cao et al [56]. On the other hand, other authors have presented the cycle without IHX, such as [54,57].…”
Section: Configurations Used In Co2 Heat Pumpsmentioning
confidence: 99%
“…Considering the most common compressor type, semi-hermetic, from the study about the development of a semi-hermetic CO2 compressor by Nekså [77] in the 20 th International Congress of Refrigeration in 2002, to the most recent studies [56,65,78,79,80,81,82], in CO2 applications, it is widely the most used type of compressor.…”
Section: Most Common Types Of Compressors For Co2 Applicationsmentioning
confidence: 99%