Comparative Analysis of Heat Pump System with IHX Using R1234yf and R134a

Abstract: This research presents an energy performance analysis of the heat pump system with internal heat exchanger (IHX). The mathematical model of the heat pump outlined in this paper has been created by the author, it is steady-state with lumped parameters. The experimental validation of the model has been carried out using R1234yf and R134a as refrigerant. The aim of this work is to compare the energy performance in a wide range of operating conditions of a monitored heat pump system using both refrigerants. Finall… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 28 publications
(31 reference statements)
0
7
0
Order By: Relevance
“…The characteristic terms of the equation [1] can be primed, related to each other, using ratios. It is useful to turn the equation [1] into a dimensionless form.…”
Section: Mathematical Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…The characteristic terms of the equation [1] can be primed, related to each other, using ratios. It is useful to turn the equation [1] into a dimensionless form.…”
Section: Mathematical Modelmentioning
confidence: 99%
“…The characteristic terms of the equation [1] can be primed, related to each other, using ratios. It is useful to turn the equation [1] into a dimensionless form. In order to formulate the hydrodynamic similarity criteria, the force of inertia is used as a reference value.…”
Section: Mathematical Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…in the further development Fig. 1 Reaction force on the lateral surface of the transpired solar collector's mathematical modeling, described by Fawaier et al [8] Distributed mass flow source has also been described by Sánta [9] during the energy analysis of heat pump systems with different refrigerants. Therefore, the balance of momentum is as follows:…”
Section: Introductionmentioning
confidence: 99%
“…Dynamic models can be used to study the dynamic behaviour [12] and the energy demand [13] of a work tool. In the present paper we perform kinematic and dynamic modelling of the rotary harrow teeth.…”
Section: Introductionmentioning
confidence: 99%