Experimental investigation on corrosion behavior of slag-cement-mortar-lined ductile iron pipe in flowing solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 54 publications
0
4
0
Order By: Relevance
“…It also proved that the complete cement mortar lining had a good protection effect by maintaining the passive state of the ductile iron surface the entire time. 17 According to the experimental results of electrode ② (ductile iron with 90% lining) as shown in Fig. 5b, the Nyquist plot was composed of a capacitive reactance arc in the high-and lowfrequency regions individually during 1-10 d. Aer it rose for 10 days, R f was about 4700 U cm 2 (ESI Table S4 †).…”
Section: Electrochemical Analysis Of the Corrosion Processmentioning
confidence: 94%
See 2 more Smart Citations
“…It also proved that the complete cement mortar lining had a good protection effect by maintaining the passive state of the ductile iron surface the entire time. 17 According to the experimental results of electrode ② (ductile iron with 90% lining) as shown in Fig. 5b, the Nyquist plot was composed of a capacitive reactance arc in the high-and lowfrequency regions individually during 1-10 d. Aer it rose for 10 days, R f was about 4700 U cm 2 (ESI Table S4 †).…”
Section: Electrochemical Analysis Of the Corrosion Processmentioning
confidence: 94%
“…CASH had also been detected in the corrosion research of the slag cement mortar, and was a hydrate gel of the cement mortar. 17 Furthermore, the SEM results clearly showed that the surface of the lining became irregular as the calcium dissolved, and the structure was gradually loosened, which had been initially eroded.…”
Section: Micro Analysis Of Corrosion Productsmentioning
confidence: 99%
See 1 more Smart Citation
“…An equivalent electrochemical circuit is a convenient model to analyze EIS data from electrochemical measurements (Zou et al 2018), and its model parameters can be obtained from the fitting of EIS data by using the Zsimpwin fitting software (Sun et al 2018). The fitting result of five specimens for curing 14 and 28 days is listed in Table 3, in which the R s and R ct1 are used to analyze the changes of the microstructure with the curing times of mortar specimens.…”
Section: Quantum Chemistrymentioning
confidence: 99%