Experimental determination of retinal damages thresholds induced by multiple picosecond laser pulses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0
1

Year Published

2000
2000
2005
2005

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 6 publications
0
5
0
1
Order By: Relevance
“…Also available are the studies by Courant et al 24 who performed an MVL study using 8-ps, 590-nm, laser pulses in a 0.2-second, 1-MHz PRF pulse train. That study did not make a direct comparison with CW exposures.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…Also available are the studies by Courant et al 24 who performed an MVL study using 8-ps, 590-nm, laser pulses in a 0.2-second, 1-MHz PRF pulse train. That study did not make a direct comparison with CW exposures.…”
Section: Discussionmentioning
confidence: 98%
“…In order to make the best comparison with published data, we have examined studies with exposure times near the one-quarter second value of our study. 3,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26 Table 3 lists several MVL values that were selected for comparison. The studies were selected based upon exposure duration, retinal image size, wavelength, and subject.…”
Section: Discussionmentioning
confidence: 99%
“…In order to make the best comparison with published data, we have examined studies with exposure times near the one-quarter second value of our study [20][21][22][23][24][25][26][27][28][29][30][31][32][33][34]. Table 4 lists several MVL values that were selected for comparison based upon not only exposure duration, but also retinal image size, wavelength, and species.…”
Section: Discussionmentioning
confidence: 99%
“…Also available are the studies by Courant et al [34] who performed an MVL study using 8-picosecond, 590 nm, laser pulses in a 0.2-second, 1-MHz PRF pulse train. That study did not make a direct comparison with CW exposures.…”
Section: Discussionmentioning
confidence: 99%
“…Les premières données expérimentales montraient que les mécanismes de dommage non linéaires ne sont pas influencés par la longueur d'onde, la durée de l'impulsion et la dimension de l'image rétinienne de la même manière que les mécanismes de dommage thermique ou thermo-acoustique. Des études histologiques de grandes et petites plages de rétine, exposées à des impulsions variant de quelques picosecondes à quelques centaines de femtosecondes et à différentes longueurs d'onde, ont montré toutefois que les effets observés sur la rétine sensorielle ont toujours pour origine les granules de mélanine de l'épithé-lium pigmentaire rétinien Courant et al, 1998Courant et al, , 1999a. D'autres études ont permis de tester différents modèles de mécanisme lésionnel basés sur des mécanismes de cavitation et de variation de pression (Cain et al, , 1998Gertsman et al, 1996;Hammer et al, 1997;Strauss et al, 1997 ;Lin et Kelly, 1998 ;Bnnkmann et al, 1999).…”
Section: Les Expositions Subnanosecondes (T < 10-ys)unclassified