Experimental assessment of bench‐scale ignitability parameters

Abstract: Summary This work aims to explore possible ways of improving the precision of ignition measurements in the cone calorimeter. Both inherent repeatability of parts of the testing equipment and operator‐dependent variations are considered. Inherent repeatability is indicated to be slightly improved if the test samples used are circular rather than square. Operator‐dependent variation is discussed in terms of the method used for determining ignition. Four procedures are compared, namely, visual observation, usage … Show more