2015
DOI: 10.1016/j.expthermflusci.2014.09.013
|View full text |Cite
|
Sign up to set email alerts
|

Experimental assessment of an absorption heat transformer prototype at different temperature levels into generator and into evaporator operating with water/Carrol mixture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
0
2

Year Published

2016
2016
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 40 publications
1
3
0
2
Order By: Relevance
“…The shown non-linear data correlate the diminished COP as function of the condenser temperature, which is the lower temperature of the thermodynamic cycle. This is in agreement with several papers for AHT [25][26][27][28][29][30][31][32][33][34][35][36] with consistent typical decreasing shape. For the same data, shown in Figure 5, the flow ratio as a function of thermal efficiency is observed as an asymptotic tendency for a lower FR value while thermal efficiency increases.…”
Section: The Usefulness Of the Dimensionless Conceptsupporting
confidence: 94%
“…The shown non-linear data correlate the diminished COP as function of the condenser temperature, which is the lower temperature of the thermodynamic cycle. This is in agreement with several papers for AHT [25][26][27][28][29][30][31][32][33][34][35][36] with consistent typical decreasing shape. For the same data, shown in Figure 5, the flow ratio as a function of thermal efficiency is observed as an asymptotic tendency for a lower FR value while thermal efficiency increases.…”
Section: The Usefulness Of the Dimensionless Conceptsupporting
confidence: 94%
“…Consequently, the operational conditions should be modified in a way to eliminate the crystallization which results in a reduction in the performance of the cycle . This problem can be resolved by adding inhibitors or boosting the solubility using ternary mixtures that would cause corrosivity and toxicity which could be a worse problem. For NH 3 /H 2 O, the evaporation enthalpy of NH 3 is less than that of H 2 O.…”
Section: Introductionmentioning
confidence: 99%
“…No mesmo contexto do tipo de solução, diferentes trabalhos na literatura vêm mostrando a importância de utilizar medidores de vazão (tipo coriolis, tubo capilar, ultrassônico, outros) como medida principal na análise do desempenho dos sistemas de refrigeração por absorção [15][16]. Esta importância de mesurar a vazão interna do refrigerante e/ou solução absorvente (LiBr/H 2 O), é necessária para o entendimento do processo de absorção e dessorção em ciclos de refrigeração por absorção, já que estes valores são necessários em validações de estudos numéricos e otimizações de componentes [17][18][19][20][21].…”
Section: Introductionunclassified