Experience With Stator Insulation Testing and Turn/Phase Insulation Failures in the Power Generation Industry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 21 publications
(6 citation statements)
references
References 23 publications
0
5
0
1
Order By: Relevance
“…In other words, an interturn insulation failure does not inevitably evolve quickly to a groundwall insulation failure. As opposed to the remarks in [68], resuming operation of a faulty generator caused damages to increase significantly, thus exposing that there is value in online FD of interturn faults. Despite recognizing its value, the acceptance of state-of-the-art methods like the ones based on electromagnetic asymmetry has been low due to their shortfalls.…”
Section: Experience With Stator Winding Failurementioning
confidence: 78%
See 2 more Smart Citations
“…In other words, an interturn insulation failure does not inevitably evolve quickly to a groundwall insulation failure. As opposed to the remarks in [68], resuming operation of a faulty generator caused damages to increase significantly, thus exposing that there is value in online FD of interturn faults. Despite recognizing its value, the acceptance of state-of-the-art methods like the ones based on electromagnetic asymmetry has been low due to their shortfalls.…”
Section: Experience With Stator Winding Failurementioning
confidence: 78%
“…On the one hand, concerning testing of ground wall insulation, there are several options: insulation resistance (IR) and polarization index (PI), DC and AC high potential (Hipot) tests, capacitance, dissipation factor, and partial discharges (PD). On the other hand, concerning testing of turn and phase insulation, there are fewer options and the surge test is the only reliable one [68]. Additionally, poor stator connections may be identified by means of thermal imaging.…”
Section: Offline Testing Of Pmsgsmentioning
confidence: 99%
See 1 more Smart Citation
“…Stator turn insulation failure leading to GW insulation breakdown and forced outage of the machine is commonly observed in the field [12]. The surge test, which is the only off-line test available for turn insulation, is somewhat controversial, as it applies a high voltage impulse to the windings that may cause the failure of good turn insulation [7].…”
Section: Insulation Testingmentioning
confidence: 99%
“…Dessa forma, garantir a integridade e as condições necessárias para o seu bom funcionamento eleva a disponibilidade do equipamento e a continuidade do processo produtivo, elevando a receita da empresa. Falhas inesperadas resultam em perdas produtivas significativas que conduzem a sérios prejuízos à empresa até o momento do restabelecimento do processo (Kim et al, 2017).…”
Section: Introductionunclassified