2015 17th European Conference on Power Electronics and Applications (EPE'15 ECCE-Europe) 2015
DOI: 10.1109/epe.2015.7311788
|View full text |Cite
|
Sign up to set email alerts
|

Experience with primary reserve supplied from energy storage system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
8
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 1 publication
1
8
0
Order By: Relevance
“…Outside the dead-band, under-frequency and over-frequency values have a nearly symmetric distribution. The grid frequency Probability Density Function (PDF), reported in Figure 10, shows that almost all the frequency perturbations are within ±50 mHz, according to frequency statistics described in other research works [6,19,26]. Figure 10.…”
Section: Results Of the Technical-economic Analysissupporting
confidence: 55%
See 2 more Smart Citations
“…Outside the dead-band, under-frequency and over-frequency values have a nearly symmetric distribution. The grid frequency Probability Density Function (PDF), reported in Figure 10, shows that almost all the frequency perturbations are within ±50 mHz, according to frequency statistics described in other research works [6,19,26]. Figure 10.…”
Section: Results Of the Technical-economic Analysissupporting
confidence: 55%
“…Outside the dead-band, under-frequency and over-frequency values have a nearly symmetric distribution. The grid frequency Probability Density Function (PDF), reported in Figure 10, shows that almost all the frequency perturbations are within ±50 mHz, according to frequency statistics described in other research works [6,19,26]. An equivalent load is connected to the HV node to represent other users either connected to the same substation or electrically close, e.g., distribution networks supplied by the HV busbar as in [41].…”
Section: Results Of the Technical-economic Analysismentioning
confidence: 64%
See 1 more Smart Citation
“…Further on, WT operation is optimal, and support is provided by the other components of the system. With that respect, energy storages systems are considered as a prominent solution [4].…”
Section: Introductionmentioning
confidence: 99%
“…Similar economic analysis of the BESS unit was carried out in [4]. However, the BESS units that were investigated in the aforementioned studies [4,6,[18][19][20][21][22], already had fixed sizes. Optimal sizing of BESS unit is one of the key aspects to consider in wind dominated power systems.…”
Section: Introductionmentioning
confidence: 99%