2018 XVII Russian Scientific and Practical Conference on Planning and Teaching Engineering Staff for the Industrial and Economi 2018
DOI: 10.1109/ptes.2018.8604169
|View full text |Cite
|
Sign up to set email alerts
|

Experience in Developing a Physical Model of Submersible Electrical Equipment for Simulator Systems: Research and Training Tasks on the Agenda of a Key Employer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…The ESP and SEM operating modes parameters determination is an important task, both from the viewpoint of the equipment correct selection at the well design stage, and from the viewpoint of energy efficiency at the its operation stage [52].…”
Section: Discussionmentioning
confidence: 99%
“…The ESP and SEM operating modes parameters determination is an important task, both from the viewpoint of the equipment correct selection at the well design stage, and from the viewpoint of energy efficiency at the its operation stage [52].…”
Section: Discussionmentioning
confidence: 99%
“…However, the equipment often installed in laboratories has significantly lower power and lower rated voltage than equipment installed on real objects. When using the approach based on the similarity theory, in the initial data processing similarity coefficients are determined, and through them a transition is made from the results obtained at laboratory benches to the parameters of the operating modes of real objects [33]. The disadvantage of this approach in modeling the load system is that it does not take into account the change in the energy characteristics of the gas turbine engines in the non-nominal operating modes.…”
Section: Discussionmentioning
confidence: 99%
“…The coefficients of the efficiency polynomials of some ESPs used at oil production enterprises are presented in Table 1 [21]. The parameters of the SEM equivalent circuit are determined by the formulas [20,22]:…”
Section: Calculation Of Esp Power Consumptionmentioning
confidence: 99%
“…The motor power factor at different load and voltage at the terminals, different from the nameplate, is calculated by the formula [22,23]:…”
Section: Calculation Of Esp Power Consumptionmentioning
confidence: 99%