Order By: Relevance
“…An important element of activities aimed at increasing energetic efficiency is the maximum use of heat that has so far been released into the atmosphere and its conversion into usable energy. Moreover, the two main expectations defined in the concept of sustainable development are the reduction of energy consumption from non-renewable sources and the effective utilization of low-grade thermal energy originating from industrial waste heat, solar power, cogeneration or exhaust gases from internal combustion engines [2].…”
Section: Environmental Demandsmentioning
confidence: 99%
See 2 more Smart Citations
“…An important element of activities aimed at increasing energetic efficiency is the maximum use of heat that has so far been released into the atmosphere and its conversion into usable energy. Moreover, the two main expectations defined in the concept of sustainable development are the reduction of energy consumption from non-renewable sources and the effective utilization of low-grade thermal energy originating from industrial waste heat, solar power, cogeneration or exhaust gases from internal combustion engines [2].…”
Section: Environmental Demandsmentioning
confidence: 99%
“…Moreover, on the markets of the Middle and the Far East, adsorption technology is intensively developed because of the possibility of desalination of seawater along with the production of cooling energy [17]. But the widespread application of adsorption chillers is limited by the following shortcomings of adsorption cooling technology: low coefficient of performance [18], large weight and volume [16], intermittent cooling [14], high initial procurement cost [14], and exploitation under vacuum conditions [2].…”
Section: Adsorption Chillersmentioning
confidence: 99%
See 1 more Smart Citation
“…Regarding the adsorption bed heat and mass transfer, fins' parameters in the packed bed adsorber have been found the most influential parameters on the adsorption system performance. Elsheniti et al [12] developed a detailed numerical model for a two-bed adsorption chiller to examine both operational and geometrical parameters. The study highlighted the importance of adapting the physical bed parameters to match each application, particularly the fin numbers.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the desorption and adsorption time can be reduced by increasing the velocity of the heat transfer fluid [27]. Elsheniti et al [28], who used COMSOL Multiphysics software for investigations, reported that the COP and specific cooling capacity could be improved by 68% and 42%, respectively, when the flow character of the heat transfer fluid was changed from laminar to turbulent.…”
Section: Introductionmentioning
confidence: 99%