1985
DOI: 10.1093/ajcp/84.2.216
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Spot-CAMP Test for the Rapid Presumptive Identification of Group B Streptococci

Abstract: A rapid Spot-CAMP test was evaluated for its ability to accurately identify colonies of Streptococcus agalactiae (Lancefield Group B) growing on primary sheep blood agar plates. The test uses a beta-lysin-containing filtrate, which is prepared from a broth culture of Staphylococcus aureus. A drop of beta-lysin filtrate is applied adjacent to a suspected group B Streptococcus (GBS) colony and the plate is incubated and then examined for a zone of synergistic hemolysis. The Spot-CAMP test demonstrated 100% corre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

1
1
0

Year Published

1986
1986
2016
2016

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 0 publications
1
1
0
Order By: Relevance
“…In summary, the sensitivity of the spot CAMP test was 99%, and the specificity was 100%, with a predictive value of 100%7 for a positive test and 98.6% for a negative test. DiPersio et al (3) and others (5, 6, 8, 10) have had similar results in previous studies of the various CAMP tests. The spot CAMP reagent, prepared either commercially or in house, is stable for at least 1 year at refrigerator temperature (9) and can be made in the laboratory or purchased commercially.…”
supporting
confidence: 81%
“…In summary, the sensitivity of the spot CAMP test was 99%, and the specificity was 100%, with a predictive value of 100%7 for a positive test and 98.6% for a negative test. DiPersio et al (3) and others (5, 6, 8, 10) have had similar results in previous studies of the various CAMP tests. The spot CAMP reagent, prepared either commercially or in house, is stable for at least 1 year at refrigerator temperature (9) and can be made in the laboratory or purchased commercially.…”
supporting
confidence: 81%
“…While this CAMP test is useful for the presumptive identification of pure cultures of suspected strains of GBS (9), the classical assay is not applicable for direct detection of GBS in primary cultures of clinical samples. Different modifications of the CAMP test have been developed for this purpose (3,10). However, none of these methods are optimal for routine examination of a large number of samples, since the procedures are relatively complicated.…”
Section: Discussionmentioning
confidence: 99%