2022
DOI: 10.4012/dmj.2022-063
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the mechanical properties and fit of 3D-printed polyetheretherketone removable partial dentures

Abstract: Compared with CAD/CAM, fused deposition modeling (FDM) 3D printing technology is simple and safe to operate and has a low cost and high material utilization rate; thus, it is widely used. The present investigation aimed to evaluate the mechanical properties and fit of polyetheretherketone (PEEK) removable partial dentures (RPDs) constructed by FDM. We analyzed mechanical properties of PEEK samples prepared by FDM, milling, or injection molding. RPDs were designed and finite element analysis models was construc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(17 citation statements)
references
References 26 publications
0
17
0
Order By: Relevance
“…Several parameters influence the printing of PEEK via FDM technology and, thus, its mechanical properties: the layer thickness [ 21 , 22 , 23 , 24 , 25 , 26 ], the nozzle diameter [ 27 ], the printing speed [ 23 , 27 ], the printing temperature [ 22 , 23 , 24 , 27 , 28 , 29 ], the chamber temperature [ 28 , 30 , 31 ], the raster angle [ 21 , 24 , 25 , 26 , 32 , 33 ], the build plate orientation [ 16 , 24 , 34 , 35 ], the infill rate [ 35 ], the PEEK modifications [ 34 , 36 , 37 ] and the possible post-treatment [ 25 , 31 , 36 , 38 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Several parameters influence the printing of PEEK via FDM technology and, thus, its mechanical properties: the layer thickness [ 21 , 22 , 23 , 24 , 25 , 26 ], the nozzle diameter [ 27 ], the printing speed [ 23 , 27 ], the printing temperature [ 22 , 23 , 24 , 27 , 28 , 29 ], the chamber temperature [ 28 , 30 , 31 ], the raster angle [ 21 , 24 , 25 , 26 , 32 , 33 ], the build plate orientation [ 16 , 24 , 34 , 35 ], the infill rate [ 35 ], the PEEK modifications [ 34 , 36 , 37 ] and the possible post-treatment [ 25 , 31 , 36 , 38 ].…”
Section: Resultsmentioning
confidence: 99%
“…Among the 18 studies included, 4 exhibited a low risk of bias [ 35 , 39 , 40 , 41 ], 14 showed a moderate risk [ 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 33 , 34 , 35 ] and none exhibited a high risk of bias ( Table 2 , Figure 2 ). Studies were badly scored in relation to the blinding of the tests and the calculation of sample size or allocation, whereas all studies [ 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 36 , 37 , 38 ] except one [ 35 ] were found to be adequate in regard to the presence of a control group.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The suitability and accuracy of removable prostheses are important and key points that can be used to evaluate their clinical performance. Good suitability facilitates maximum support, retention, and stability in removable prostheses [ 11 ], and it helps avoid adverse mechanical stimulation and the negative effects caused by biological factors during masticatory force [ 12 ]. An inadequate fit may accelerate abutment movement and lower masticatory efficiency, with poor retention being the chief problem during functional movement [ 13 ].…”
Section: Accuracy Of Cad/cam Fabrication For Peek Materialsmentioning
confidence: 99%