Evaluation of the Electric Field above a Specimen Surface during SIMS Analysis

Abstract: Secondary ion mass spectrometry (SIMS) has been a central analytical technique for the microelectronics industry. More precise analysis has become important along with the development and process monitoring of integrated circuits (ICs) production. The level of quantitative analysis is influenced by random and systematic uncertainties. The origin of these uncertainties in SIMS have been well documented by Werner. 1 A number of authors have reported measurement techniques to minimize the contribution of uncertai… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2000
2000
2001
2001

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…Becker et al 139 addressed the problem of quantification in the determination of long-lived radionuclides by LA-ICP-MS, for which no suitable standard RMs were available. Their approach was to make synthetic standards by doping a graphite or concrete matrix with long-lived radionuclides, such as 237 Np, 99 Tc, 232 Th, 233 U, 235 U or 238 U. Two calibration procedures were considered: the correction of analytical results with experimentally determined relative sensitivity coefficients; and the use of calibration curves and solution calibration by coupling LA-ICP-MS to an ultrasonic nebulizer.…”
Section: Laser Ablation It Has Become Clear That La-icp-msmentioning
confidence: 99%
See 3 more Smart Citations
“…Becker et al 139 addressed the problem of quantification in the determination of long-lived radionuclides by LA-ICP-MS, for which no suitable standard RMs were available. Their approach was to make synthetic standards by doping a graphite or concrete matrix with long-lived radionuclides, such as 237 Np, 99 Tc, 232 Th, 233 U, 235 U or 238 U. Two calibration procedures were considered: the correction of analytical results with experimentally determined relative sensitivity coefficients; and the use of calibration curves and solution calibration by coupling LA-ICP-MS to an ultrasonic nebulizer.…”
Section: Laser Ablation It Has Become Clear That La-icp-msmentioning
confidence: 99%
“…Two calibration procedures were considered: the correction of analytical results with experimentally determined relative sensitivity coefficients; and the use of calibration curves and solution calibration by coupling LA-ICP-MS to an ultrasonic nebulizer. The LOD of long-lived radionuclides investigated in a concrete matrix were determined in the pg g 21 range, for example 50 pg g 21 for 237 Np by quadrupole LA-ICP-MS and 1.3 pg g 21 for 233 U by double-focusing magnetic sector LA-ICP-MS. Furthermore, LA-ICP-MS allowed precise and accurate isotope ratio measurements of Th and U in solid samples.…”
Section: Laser Ablation It Has Become Clear That La-icp-msmentioning
confidence: 99%
See 2 more Smart Citations