2021
DOI: 10.1007/s00590-021-03069-y
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Staphylococcus aureus and Candida albicans biofilms adherence to PEEK and titanium-alloy prosthetic spine devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 31 publications
1
8
0
Order By: Relevance
“…The PEEK surfaces were significantly rougher than the cp-Ti and Ti6Al4V surfaces. The bacterial retention values for Streptococcus sanguinis were significantly higher on PEEK surfaces as compared to Ti6Al4V, which is in accordance with the study investigated by da Rocha et al [ 35 ]. It was apparently indicated that Streptococcus aureus and Candida albicans adhesion were more likely to occur on PEEK surfaces than on titanium surfaces.…”
Section: Characteristics Of Peek and Its Composite Materialssupporting
confidence: 91%
See 2 more Smart Citations
“…The PEEK surfaces were significantly rougher than the cp-Ti and Ti6Al4V surfaces. The bacterial retention values for Streptococcus sanguinis were significantly higher on PEEK surfaces as compared to Ti6Al4V, which is in accordance with the study investigated by da Rocha et al [ 35 ]. It was apparently indicated that Streptococcus aureus and Candida albicans adhesion were more likely to occur on PEEK surfaces than on titanium surfaces.…”
Section: Characteristics Of Peek and Its Composite Materialssupporting
confidence: 91%
“…The characteristics of the materials employed for use in removable prostheses must be resistant to microbial colonization [ 35 ]. Chemical composition, surface-free energy, and surface roughness have the potential to affect bacterial adherence [ 36 ].…”
Section: Characteristics Of Peek and Its Composite Materialsmentioning
confidence: 99%
See 1 more Smart Citation
“…Subsequently, the tubes were closed and sonicated at 40 kHz for 30 minutes. The 100 mcL of aliquot was plated at 6log 10 , 4log 10 , 2log 10 , and neat dilutions to estimate colony counts 12 . For dry biofilm analysis, the remaining liquid was filtered through a 0.22 mm membrane 13 .…”
Section: Post-use Studymentioning
confidence: 99%
“…PEEK is frequently utilized in applications such as implants, 28 dental materials, 29 orthopedic devices, 30 biocompatible materials, 31 endoscopy instruments, 32 and diagnostic devices. 33 Polylactic acid (PLA) is derived from natural resources and is classified as a thermoplastic polymer. PLA possesses remarkable characteristics including renewability, sustainability, and biocompatibility.…”
Section: Introductionmentioning
confidence: 99%