2011
DOI: 10.1093/chromsci/bmr006
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Septa Quality for Automatic SPME-GC-MS Trace Analysis

Abstract: The vials used for the preparation of breath samples for automated solid-phase microextraction-gas chromatography-mass spectrometry analysis are crimped with septa. These septa often emit specific volatile organic compounds (VOCs) confounding the measurement results of breath samples. In the current paper, 14 different brands of magnetic caps with silicone-polytetrafluoroethylene (PTFE), butyl-PTFE, or butyl rubber septa were tested. The total emission of septa over a 4 h period was also evaluated. The tested … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…Previous mass spectrometric research has reported vulcanizing agents and antioxidants leaching into reaction mixtures. [116][117][118][119] The incidental contact of solvent to rubber septa results in the leaching of interfering ions into the reaction mixture, and this process is especially efficient when the reaction solvent is heated. Primary and secondary antioxidants are often used to prolong or inhibit the free radical chain mechanism of oxidative decomposition in rubber, plastics, and foods.…”
Section: Introductionmentioning
confidence: 99%
“…Previous mass spectrometric research has reported vulcanizing agents and antioxidants leaching into reaction mixtures. [116][117][118][119] The incidental contact of solvent to rubber septa results in the leaching of interfering ions into the reaction mixture, and this process is especially efficient when the reaction solvent is heated. Primary and secondary antioxidants are often used to prolong or inhibit the free radical chain mechanism of oxidative decomposition in rubber, plastics, and foods.…”
Section: Introductionmentioning
confidence: 99%
“…Gas chromatographymass spectrometry (GC-MS) [5][6][7][8][9][10] has been regarded as a gold-standard method for trace gas analysis for its high sensitivity and high accuracy. However, the GC-MS method is not suitable for breath analysis using a large number of samples due to its complicated sample preparation procedure, time-consuming test process, and high instrumentation and operational costs.…”
Section: Introductionmentioning
confidence: 99%
“…The above procedure has been widely used for the preparation of standard mixtures for gas analyzers. 46,47 The calibration curves were obtained based on the analysis of the gaseous mixture of the standard compounds diluted with nitrogen, as shown in Fig. 3(b).…”
Section: Effect Of Ow Rate Of Exhaled Breath On Detection Sensitivitymentioning
confidence: 99%