2011
DOI: 10.1159/000327914
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Performance of Measurement of Faecal α1-Antitrypsin Clearance and Technetium-99m Human Serum Albumin Scintigraphy in Protein-Losing Enteropathy

Abstract: Background and Aim: Our study aimed to compare the performance of faecal α1-antitrypsin clearance (AATC) and radiolabelled human serum albumin (HSA) scintigraphy in protein-losing enteropathy (PLE). Methods: Patients studied by both AATC and technetium-99m (99mTc)-labelled HSA scintigraphy were recruited and categorized into PLE and non-PLE groups based on clinical and laboratory findings. The performance of AATC and 99mTc-labelled HSA scintigraphy was evaluated using clinical … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(16 citation statements)
references
References 16 publications
1
14
1
Order By: Relevance
“…[22][23][24] Chau et al found that positive images in the early phase of the scan are more useful in identifying the primary site of protein loss and detecting multifocal involvement. 21 Our observation does not support this finding because most of our patients showed diffuse inflammatory change in the GI tract and the early positive image may represent intermittent protein leakage at this instant only.…”
Section: Acquired Form Of Lymphangiectasiacontrasting
confidence: 73%
See 1 more Smart Citation
“…[22][23][24] Chau et al found that positive images in the early phase of the scan are more useful in identifying the primary site of protein loss and detecting multifocal involvement. 21 Our observation does not support this finding because most of our patients showed diffuse inflammatory change in the GI tract and the early positive image may represent intermittent protein leakage at this instant only.…”
Section: Acquired Form Of Lymphangiectasiacontrasting
confidence: 73%
“…99m Tc-labeled HSA had very high sensitivity (95.8%) in the detection of protein leakage in our study, comparable to the previous studies. 20,21 Chau et al found superior performance of the 99mTc-labelled HSA scintigraphy over fecal AATC with higher sensitivity. 21 However, there are several pitfalls of 99m Tc-labeled HSA scintigraphy for PLE.…”
Section: Non-necrotizing Mesenteric or Intestinalmentioning
confidence: 99%
“…The detection rate of protein leakage in PLE was very good (97.3%) in our study, compared with previous studies [30,31]. Chau and colleagues found 99m Tc-labeled HSA scintigraphy to be superior to fecal AATC, with higher sensitivity.…”
Section: Discussionsupporting
confidence: 56%
“…99 m Tc-HSA scintigraphy is regarded as the diagnostic tool of choice for patients with PLE [2] , [3] , [35] , as it has very high sensitivity for diagnosis and localization of PLE [36] – [38] . However, its application is limited because many hospitals are not able to perform the procedure.…”
Section: Discussionmentioning
confidence: 99%