2007
DOI: 10.1016/j.ajo.2006.11.030
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Keratoconus in Asians: Role of Orbscan II and Tomey TMS-2 Corneal Topography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
55
1
3

Year Published

2008
2008
2022
2022

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 76 publications
(64 citation statements)
references
References 22 publications
5
55
1
3
Order By: Relevance
“…Lim et al 24 found that the mean values of maximum posterior elevation and irregularity were significantly higher in keratoconus and keratoconus-suspect eyes than in control eyes. 24 The existence of a correlation between the radius of curvature and the asphericity of the anterior and posterior surfaces in the same patient is controversial.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…Lim et al 24 found that the mean values of maximum posterior elevation and irregularity were significantly higher in keratoconus and keratoconus-suspect eyes than in control eyes. 24 The existence of a correlation between the radius of curvature and the asphericity of the anterior and posterior surfaces in the same patient is controversial.…”
Section: Discussionmentioning
confidence: 98%
“…24 The existence of a correlation between the radius of curvature and the asphericity of the anterior and posterior surfaces in the same patient is controversial. Tomidokoro et al 25 found a significant positive correlation between spherical power, regular astigmatism, asymmetry, and higher-order irregularity of the anterior and posterior surfaces.…”
Section: Discussionmentioning
confidence: 99%
“…More recent prospective studies with larger patient samples have proposed that the majority of fellow eyes developing keratoconus might do so in the first 6 years following baseline diagnosis of the contralateral eye, with younger age and the magnitude of asymmetry being the principal risk factors [15]. These studies have reported a higher prevalence of asymmetric curvature patterns, between 70% [16] and 80% [15] in clinically normal fellow eyes. We found a greater prevalence of asymmetric patterns proportional to the exposure to risk of keratoconus (56% fellow eye, 44% OD relatives, and 32% OD controls).…”
Section: Discussionmentioning
confidence: 89%
“…O novo sistema cromático facilita a captura da imagem com segmentação dos discos que se apresentam como anéis coloridos conseguindo através do reflexo corresponder ao algoritmo no cone, diferenciando-se da topografia convencional pela separação em três cores com nitidez e consequente digitalização e processamento da imagem (5) . (10) . Um trabalho anterior compara dois sistemas videoceratográficos em pacientes com ceratocone e os resultados não diferiram entre os dois aparelhos nas medidas da direção do astigmatismo e na diferença ceratométrica (11) .…”
Section: Discussionunclassified