2014
DOI: 10.1016/j.radphyschem.2014.02.014
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of entrance surface air kerma in pediatric chest radiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 5 publications
0
2
1
Order By: Relevance
“…Our findings showed that the median ESD values or the number of X-ray procedures performed for each neonate were higher than those reported previously (Sutton et al, 1998;Ono et al, 2003;Donadieu et al, 2006;Bader et al, 2007;Baert et al, 2008;Puch-Kapst et al, 2009). Although low voltage-high tube current time product combination shows good image quality, it could lead to high ESD (Frayre et al, 2012;Porto et al, 2014). Therefore, the use of low tube voltage techniques and lack of specialized neonatal radiologic technicians may explain the higher ESD in our study.…”
Section: Discussioncontrasting
confidence: 61%
“…Our findings showed that the median ESD values or the number of X-ray procedures performed for each neonate were higher than those reported previously (Sutton et al, 1998;Ono et al, 2003;Donadieu et al, 2006;Bader et al, 2007;Baert et al, 2008;Puch-Kapst et al, 2009). Although low voltage-high tube current time product combination shows good image quality, it could lead to high ESD (Frayre et al, 2012;Porto et al, 2014). Therefore, the use of low tube voltage techniques and lack of specialized neonatal radiologic technicians may explain the higher ESD in our study.…”
Section: Discussioncontrasting
confidence: 61%
“…The research data used is the conformity test data for X-ray device Kasih Ibu Hospital, Kedonganan, Badung, Bali. Information on radiation output dose data such as field area 20 cm × 20 cm, tube current 200 mA, setting time 0.1 s, SID 100, and average patient thickness (tp) for PA projection of 23 cm (Costa & Pelegrino, 2014;Porto et al, 2014). With the test data for the suitability of the X-ray tube voltage, it is possible to determine the dose in Gy and the radiation output in Gy/mAs which is exemplified as follows:…”
Section: Resultsmentioning
confidence: 99%
“…Without the suggested spectrum stripping procedure, the discrepancy between the derived spectrum and the reference spectrum was over 63%, but it was reduced to less than 0.2%. The kerma of the chest wall in kids and teens was investigated by Porto et al [ 6 ]. According to the findings of this study, air tension falls as tube voltage rises and exposure falls.…”
Section: Introductionmentioning
confidence: 99%