2021
DOI: 10.21744/irjeis.v7n6.1953
|View full text |Cite
|
Sign up to set email alerts
|

General radiographic patient dose monitoring using conformity test data

Abstract: Currently, the Nuclear Energy Supervisory Agency (BAPETEN) is actively guiding users or license holders related to patient protection against radiation hazards or often referred to as radiation protection and safety on medical exposure. Protection against medical exposure became a big issue when the mandatory compliance test on X-ray equipment for diagnostic and interventional radiology was introduced. In addition, license holders through their medical practitioners are also required to use the level of medica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 15 publications
0
2
0
1
Order By: Relevance
“…Meta-analyses are prone to publication bias, whereby studies exhibiting significant or positive outcomes are more inclined to be published and incorporated into the analysis. The time constraints associated with rapid reviews may result in a restricted ability to explore unpublished studies or perform a comprehensive search of the gray literature, thereby elevating the possibility of overlooking significant studies and introducing partiality into the meta-analysis Putra et al, 2021;Zikos et al, 2014).…”
Section: Abudalbouh L a (2023) Electronic Nursing Documentation Inter...mentioning
confidence: 99%
“…Meta-analyses are prone to publication bias, whereby studies exhibiting significant or positive outcomes are more inclined to be published and incorporated into the analysis. The time constraints associated with rapid reviews may result in a restricted ability to explore unpublished studies or perform a comprehensive search of the gray literature, thereby elevating the possibility of overlooking significant studies and introducing partiality into the meta-analysis Putra et al, 2021;Zikos et al, 2014).…”
Section: Abudalbouh L a (2023) Electronic Nursing Documentation Inter...mentioning
confidence: 99%
“…Dalam hal ini EI dapat digunakan sebagai indikator eksposure yang digunakan pada pemeriksaan tertentu. Hal ini dapat menjadi program quality control (QC) manajemen dosis yang berguna sebagai alat diagnostik untuk monitoring nilai eksposure [13].…”
Section: Exposure Index (Ei)unclassified
“…The perpendicularity of the X-ray beam is very necessary because it involves the resulting image [4]- [6]. Problems that often arise related to these parameters are the occurrence of image shifts and anode focus which results in a less sharp, distorted, and ghosted image so that if this happens, re-irradiation must be carried out which causes unnecessary radiation to increase to the patient [3], [7]- [12]. As happened in a 2018 study where Kesawa Sudarsih et al stated that in RSUD K.R.M.T Wongsonegoro Semarang when performing a radiograph, the collimator area was set wide, did not match the size of the object, and the final result was cut off so the patient had to repeat the radiograph.…”
Section: Introductionmentioning
confidence: 99%