2004
DOI: 10.1016/j.chroma.2003.10.030
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of different liquid chromatography–electrospray mass spectrometry systems for the analysis of heterocyclic amines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
35
2

Year Published

2004
2004
2010
2010

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 48 publications
(40 citation statements)
references
References 38 publications
3
35
2
Order By: Relevance
“…Moreover, according to the signal 3Â the peak-topeak noise, the calculated detection limits ranged between 11 nM (harmalol) and 90 nM (harmaline). These detection limits are considerably better than those reported in the literature using HPLC with UV [9], fluorimetric [8] and chemiluminescent [8] detection, and similar to those obtained using MS detection [6]. Moreover, the ranges of linearity obtained using amperometric detection at CNT-CGE are much wider than those reported in the literature.…”
Section: Lc-ec Detection At the Cnt-gcesupporting
confidence: 67%
See 2 more Smart Citations
“…Moreover, according to the signal 3Â the peak-topeak noise, the calculated detection limits ranged between 11 nM (harmalol) and 90 nM (harmaline). These detection limits are considerably better than those reported in the literature using HPLC with UV [9], fluorimetric [8] and chemiluminescent [8] detection, and similar to those obtained using MS detection [6]. Moreover, the ranges of linearity obtained using amperometric detection at CNT-CGE are much wider than those reported in the literature.…”
Section: Lc-ec Detection At the Cnt-gcesupporting
confidence: 67%
“…The HPLC separation and determination of the b-carboline alkaloids were carried out using an isochratic elution and a C 18 reversed-phase column [1,6,7]. The mobile phase employed consisted of methanol/acetonitrile À 0.05 mol L À1 HPO 2À 4 solution of pH 9.0 [9,26].…”
Section: Lc-ec Detection At the Cnt-gcementioning
confidence: 99%
See 1 more Smart Citation
“…The gradient elution program and the MS conditions were as previously described [30]. Normalized collision energies (NCE), time schedule and MS/MS parameters are given in Table 1.…”
Section: Analytical Conditionsmentioning
confidence: 99%
“…For all tested compounds and instrumental setups, linear response was observed from the LOQ up to 1 ppm, implying a linear range two orders of magnitude larger for the triple quadrupole instrument, because of its lower LOD. The method was applied for HAA determination in lyophilized beef extract 82,199 . A similar study was carried out by HPLC with multiple ion detection-APCI-MS, which showed high sensitivity on measuring the intensities of the [M + H] + ions.…”
Section: B Liquid Chromatography 1 Mass Spectrometric Detectionmentioning
confidence: 99%