Evaluation of Central and Peripheral Corneal Thickness with Ultrasound Biomicroscopy in Normal and Keratoconic Eyes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
37
0
5

Year Published

1998
1998
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 64 publications
(43 citation statements)
references
References 0 publications
1
37
0
5
Order By: Relevance
“…[34][35][36][37][38][39] Mandell and Polse 34 pioneered the investigations of corneal thickness profile in a study using a modified Haag-Streit optical pachymeter with an electronic recording system to document the variation in thickness over the horizontal meridian measured at different angles. In their study, the difference between the central and the peripheral measurements was much greater in eyes with keratoconus; it was most significant at the 35-degree position, where the authors found a difference greater than 0.085 mm as pathognomonic of keratoconus.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[34][35][36][37][38][39] Mandell and Polse 34 pioneered the investigations of corneal thickness profile in a study using a modified Haag-Streit optical pachymeter with an electronic recording system to document the variation in thickness over the horizontal meridian measured at different angles. In their study, the difference between the central and the peripheral measurements was much greater in eyes with keratoconus; it was most significant at the 35-degree position, where the authors found a difference greater than 0.085 mm as pathognomonic of keratoconus.…”
Section: Discussionmentioning
confidence: 99%
“…Avitabile et al 35 defined a keratoconus index that evaluated the ratio between the mean peripheral corneal thickness and the thinnest point measured by ultrasound biomicroscopy (UBM). The keratoconus index proved to be very sensitive, detecting significantly different values between normal corneas and keratoconic corneas (P!.001, Student t test).…”
Section: Discussionmentioning
confidence: 99%
“…As long as the cornea treated has a minimum thickness of 400 lm (as recommended), the corneal endothelium will not experience damage, nor will deeper structures such as lens and retina. The light source should provide a homogenous irradiance, avoiding hot spots [69][70][71][72][73].…”
Section: Risks and Side Effectsmentioning
confidence: 99%
“…Ultrasonik yöntemler aras›nda ultrasonik pakimetre ve ultrasonik biyomikroskop (UBM), optik yöntemler aras›nda ise speküler mikroskopi, optik koherans tomografi, taray›c› slit kornea topografisi, konfokal mikroskopi ve Pentacam Scheimpflug sistem say›labilir. 1,[7][8][9][10][11][12][13][14][15][16][17] Ultrasonik pakimetri, ucuz ve kolay uygulanabilir bir teknoloji olmas›, ölçümlerinin yüksek tekrarlanabilirlikte ve güvenilirlikte olmas› nedeniyle klinik uygulamalarda yayg›n olarak kullan›lmaktad›r. 13,[18][19][20] Korneaya temas etmesi en önemli dezavantaj›d›r ve epitel defektlerine ve enfeksiyonlara yol açabilmektedir.…”
Section: Giriflunclassified