2014
DOI: 10.1016/j.fusengdes.2014.03.037
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of applicability of laser-based distance meter to measure Li-jet thickness for IFMIF/EVEDA project

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 21 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…The laser probe (LP) method [13,14] is a laser-based non-contact method that can be used to measure jet thickness and wave height. We developed the LP method following the analysis method (zero-up crossing method) used in the random-phase/amplitude model, which is also employed in the contact probe method.…”
Section: Non-contact-type Diagnostic Tools and Methodsmentioning
confidence: 99%
“…The laser probe (LP) method [13,14] is a laser-based non-contact method that can be used to measure jet thickness and wave height. We developed the LP method following the analysis method (zero-up crossing method) used in the random-phase/amplitude model, which is also employed in the contact probe method.…”
Section: Non-contact-type Diagnostic Tools and Methodsmentioning
confidence: 99%
“…The stability of the Li target was evaluated by the laser-probe method [5]. Table 3 summarizes the average thickness of the Li target and the mean and maximum wave amplitudes on its surface.…”
Section: Flow Appearance and Stability Of LI Targetmentioning
confidence: 99%
“…The laser-probe method is presented in detail in Ref. [5]. As a result of measurements in the entire beam-footprint zone with an interval of 5-15 mm, a nonuniformity in the beam-footprint zone, which is defined as the maximum minus minimum thickness, was 0.16 mm at the nominal velocity of 15 m/s.…”
Section: Flow Appearance and Stability Of LI Targetmentioning
confidence: 99%
See 1 more Smart Citation
“…On the other hand, the solubility of nitrogen and hydrogen in lithium is large even at around the melting point of lithium; therefore, both elements should be removed from the liquid lithium chemically with other traps, which are so called hot traps. The related recent activities of lithium purification studies were reported in the references [8][9][10][11][12][13][14][15][16][17][18], and the content of the lithium test facility of IFMIF have been reported in the references [8,9,[19][20][21][22][23][24][25][26][27].…”
Section: Introductionmentioning
confidence: 99%