2018
DOI: 10.4172/2157-7064.1000411
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of an Ion Chromatography Method for Quantitating Sulfate in Plasma, Serum and Urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…This finding suggests that the turbidometric microassay underestimates the sulfate level in plasma and urine by at least 34 %. We found that to be the case when we compared sulfate levels measured with the turbidometric microassay and an ion chromatography method [12] . The turbidometric microassay consistently yielded sulfate levels that were 32 % and 33 % lower in pig plasma ( n = 33) and urine ( n = 5) samples, respectively, when compared to the ion chromatography method.…”
Section: Methods Validationmentioning
confidence: 89%
See 2 more Smart Citations
“…This finding suggests that the turbidometric microassay underestimates the sulfate level in plasma and urine by at least 34 %. We found that to be the case when we compared sulfate levels measured with the turbidometric microassay and an ion chromatography method [12] . The turbidometric microassay consistently yielded sulfate levels that were 32 % and 33 % lower in pig plasma ( n = 33) and urine ( n = 5) samples, respectively, when compared to the ion chromatography method.…”
Section: Methods Validationmentioning
confidence: 89%
“…Several methods for measuring sulfate in biological samples have been described, but many of those methods use toxic reagents [11] or require high-cost specialized equipment such as ion chromatography [12] . A relatively low-cost and low-hazard methodology is the turbidometric assay that uses BaCl 2 agarose solution to precipitate sulfate [13] .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Plasma samples are transported to the lead study site where they are batch-analysed. Plasma sulfate concentrations are measured using ion chromatography with suppressed conductivity detection using a Dionex ICS2000, as previously described 48. Plasma magnesium concentrations are quantitated as per routine testing using a Vitros 5.1 FS chemistry analyser.…”
Section: Methodsmentioning
confidence: 99%
“…The cotton wool ball is thawed and centrifuged to obtain urine for analysis. Urinary and plasma sulfate concentrations are measured as previously described 48. Urinary and plasma creatinine is measured as per routine testing using a Vitros 5.1 FS chemistry analyser.…”
Section: Methodsmentioning
confidence: 99%