2022
DOI: 10.1016/j.jpba.2022.114900
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of 4 quantification methods for monitoring 16 antibiotics and 1 beta-lactamase inhibitor in human serum by high-performance liquid chromatography with tandem mass spectrometry detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 27 publications
1
11
0
Order By: Relevance
“…We used a deuterated chemical analog of DBV as IS. This is in agreement with the study of Seraissol et al [ 21 ] and different from other methods published previously [ 17 , 18 , 19 ]. The major advantage granted by using a deuterated IS is the high accuracy achieved in compensating for extraction yield and matrix effect variations of patients’ samples whose content and composition of endogenous and exogenous compounds may be very different.…”
Section: Discussionsupporting
confidence: 93%
See 1 more Smart Citation
“…We used a deuterated chemical analog of DBV as IS. This is in agreement with the study of Seraissol et al [ 21 ] and different from other methods published previously [ 17 , 18 , 19 ]. The major advantage granted by using a deuterated IS is the high accuracy achieved in compensating for extraction yield and matrix effect variations of patients’ samples whose content and composition of endogenous and exogenous compounds may be very different.…”
Section: Discussionsupporting
confidence: 93%
“…The aim of this study was to develop and validate a fast and simple analytical method for measuring DBV concentrations in plasma microsamples by means of a liquid chromatography-isotope dilution tandem mass spectrometry (ITD LC-MS/MS) technique using as internal standard the exa-deuterated analog of DBV (DBV-d6), similar to Seraissol et al [ 21 ].…”
Section: Introductionmentioning
confidence: 99%
“…HPLC can effectively exclude the influence of digoxin metabolites in patients on the detection results and has high specificity for digoxin. The results obtained using this method were accurate and highly sensitive. However, it has a certain requirement for operational technology, and thus this method is preferred when the sample size is small. Radioimmunoassay (RIA) combines the high sensitivity of radionuclide tracing technology and the high specificity of immunochemistry.…”
Section: Resultsmentioning
confidence: 99%
“…47 In addition, difficulties such as the lack of commercial kits for beta-lactam serum measurement, absence of education on beta-lactam TDM, and low beta-lactam serum stability (eg, 3 hours for cefepime and piperacillin-tazobactam at ambient temperature) are important barriers to be considered in daily routine. 48…”
Section: Beta-lactamsmentioning
confidence: 99%
“…47 In addition, difficulties such as the lack of commercial kits for beta-lactam serum measurement, absence of education on beta-lactam TDM, and low beta-lactam serum stability (eg, 3 hours for cefepime and piperacillin-tazobactam at ambient temperature) are important barriers to be considered in daily routine. 48 Currently, beta-lactam TDM is not widely used in clinical practice, and there is no conclusive analysis of its cost benefits. 49 An multicenter randomized clinical trial in the Netherlands (the DOLPHIN study) was designed to assess the efficacy and cost benefit of beta-lactam and fluoroquinolone TDM.…”
Section: Beta-lactamsmentioning
confidence: 99%