Evaluation and Validation of the Detection of soluble Triggering Receptor Expressed on Myeloid Cells 1 by Enzyme-linked immunosorbent Assay

Abstract: Triggering receptor expressed on myeloid cells (TREM)-1 plays an important role in innate immune responses and is upregulated under infectious as well as non-infectious conditions. In addition, a soluble TREM-1 variant (sTREM-1) is detectable in sera or bronchoalveolar-lavage fluids from patients. Currently, various studies are difficult to compare, since the methods of detection by enzyme-linked immunosorbent assays (ELISA) vary among different research groups. In this study, we compared three different s-TRE… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 37 publications
(60 reference statements)
0
9
0
Order By: Relevance
“…When comparing our results to other studies, it has to be considered, that there are several ELISAs for the detection of sTREM-1 available, which might differ significantly as indicated by the range of cut-off values used in different studies 29 . The ELISA used the study of Hasibeder et al .…”
Section: Discussionmentioning
confidence: 94%
See 2 more Smart Citations
“…When comparing our results to other studies, it has to be considered, that there are several ELISAs for the detection of sTREM-1 available, which might differ significantly as indicated by the range of cut-off values used in different studies 29 . The ELISA used the study of Hasibeder et al .…”
Section: Discussionmentioning
confidence: 94%
“…The ELISA used the study of Hasibeder et al . 29 is most related to our test. We requested data on sTREM-1 levels in healthy volunteers (n = 4) from the authors (personal communication).…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…This might be due to not only very good inflammation suppression using optimal antimicrobial treatment[ 18 30 ] but also the fact that sTREM-1 is susceptible to many serum components such as complement that interfere and lead to big variability between results among different manufacturers. [ 18 ] Considering previously mentioned limitations of sTREM-1 detection methods, sTREM-1 ELISA test has to be improved to be suitable for clinical application[ 31 ] to be sure that the problem does not lie in variability of the tests. In addition, some studies showed that measurement of sTREM-1 at the site of the infection (such as cerebrospinal fluid and bronchoalveolar lavage) appears to have higher clinical significance than serum or plasma measurements.…”
Section: Discussionmentioning
confidence: 99%
“…One of the reasons for this inconsistency could lie in the previously mentioned fact that commercially available ELISA tests for sTREM-1 are very susceptible to endogenous and exogenous interferences that can be seen from variability between different kits. [ 18 ]…”
Section: Discussionmentioning