2016
DOI: 10.1167/tvst.5.6.11
|View full text |Cite
|
Sign up to set email alerts
|

Evaluating the Biostability of Yellow and Clear Intraocular Lenses with a System Simulating Natural Intraocular Environment

Abstract: PurposeBlue light–filtering intraocular lenses (IOLs) are thought to protect the retina from blue light damage after cataract surgery, and the implantation of yellow-tinted IOLs has been commonly used in cataract surgery. To our knowledge, this is the first investigation measuring the long-term biostability of yellow-tinted IOLs using an in vitro system simulating natural intraocular environment.MethodsSix hydrophobic acrylic IOLs, three clear IOLs, and three yellow-tinted IOLs were included in the study. Each… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…Materials 2020, 13, x 2 of 10 effect [8,[10][11][12][13]. Cataract surgery involving the implantation of clear IOLs has increased light transmittance at approximately 410 nm that might be associated with the risk of age-related macular degeneration [14]. To minimize this, yellow-tinted IOLs that absorb blue light are available [3,[14][15][16][17][18][19].…”
Section: Iolsmentioning
confidence: 99%
See 2 more Smart Citations
“…Materials 2020, 13, x 2 of 10 effect [8,[10][11][12][13]. Cataract surgery involving the implantation of clear IOLs has increased light transmittance at approximately 410 nm that might be associated with the risk of age-related macular degeneration [14]. To minimize this, yellow-tinted IOLs that absorb blue light are available [3,[14][15][16][17][18][19].…”
Section: Iolsmentioning
confidence: 99%
“…Cataract surgery involving the implantation of clear IOLs has increased light transmittance at approximately 410 nm that might be associated with the risk of age-related macular degeneration [ 14 ]. To minimize this, yellow-tinted IOLs that absorb blue light are available [ 3 , 14 , 15 , 16 , 17 , 18 , 19 ]. A bulky haptic, such as those of the foldable one-piece IOLs can hamper capsular bend formation and adhesion [ 13 , 20 , 21 , 22 , 23 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, most of the AH and VH secreted into the eye consist of water containing small amounts of various substances (Table ). , AH and VH contain various ions, as well as various metabolites such as glucose, cholesterol, amino acids, proteins, oxygen, and carbon dioxide. AH, VH, and tears have similar components, but with slight differences.…”
Section: Anatomy and Physiology Of The Eyementioning
confidence: 99%