2018
DOI: 10.1364/optica.5.000032
|View full text |Cite
|
Sign up to set email alerts
|

Evaluating image resolution in stimulated emission depletion microscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
93
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
4
1

Relationship

2
8

Authors

Journals

citations
Cited by 95 publications
(94 citation statements)
references
References 21 publications
1
93
0
Order By: Relevance
“…The use of 2D test samples for testing lateral resolution of localisation based super-resolution has already been covered extensively in the literature [25,[29][30][31]57]. Our focus on 3D samples and the repurposing of a 2D test sample for establishing qPAINT analysis should help to further establish the use of test samples for this more complex set of SMLM properties and analysis strategies.…”
Section: Discussionmentioning
confidence: 99%
“…The use of 2D test samples for testing lateral resolution of localisation based super-resolution has already been covered extensively in the literature [25,[29][30][31]57]. Our focus on 3D samples and the repurposing of a 2D test sample for establishing qPAINT analysis should help to further establish the use of test samples for this more complex set of SMLM properties and analysis strategies.…”
Section: Discussionmentioning
confidence: 99%
“…Thanks to the nature of how images are acquired when scanning the sample using the resonant mirror, each raw image contains a mirror image 67 . Having independently acquired these twin images, they then need to be translated so that there is no drift between them, as it can influence the FRC result 66 . We use the subpixel registration algorithm based on the cross correlation of the images 68 .…”
Section: Noise Problem and Resolution Quantification In Sted Imagingmentioning
confidence: 99%
“…Under high light doses, especially for a STED process in order to achieve high resolution, yet, fluorophores tend to be exposed in high risk of photobleaching. Thus, photobleaching leads to signal reduction or information loss, to some extent, affecting to the image quality which in turn asserts limitation to the further improvement of spatial resolution of STED microscopy (Tortarolo et al, 2018). Because phototoxicity is strictly connected with photobleaching, the decrease of photobleaching effect helps to ameliorate phototoxicity phenomenon.…”
Section: Introductionmentioning
confidence: 99%