European Society of Cardiology-Proposed Diagnostic Echocardiographic Algorithm in Elective Patients with Clinical Suspicion of Infective Endocarditis: Diagnostic Yield and Prognostic Implications in Clinical Practice

Abstract: Background:Echocardiography plays a central role in diagnosing infective endocarditis (IE). Accordingly, the European Society of Cardiology (ESC) has proposed a diagnostic echocardiographic algorithm. However, new studies are still needed to evaluate the degree of implementation of these guidelines in clinical practice and their consequences on incidence and prognosis of IE.Aim:This study aims to investigate the diagnostic yield of the ESC proposed echocardiographic algorithm in patients with suspected IE. We … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 14 publications
0
5
0
2
Order By: Relevance
“…In our study, CT thickness was significantly lower than the echographic one, as a result of the higher CT spatial resolution. Multimodality imaging and a diagnostic algorithm have been already underlined by current guidelines,[262728] and other studies comparing multislice CT and TEE have never assessed this topic.…”
Section: Discussionmentioning
confidence: 99%
“…In our study, CT thickness was significantly lower than the echographic one, as a result of the higher CT spatial resolution. Multimodality imaging and a diagnostic algorithm have been already underlined by current guidelines,[262728] and other studies comparing multislice CT and TEE have never assessed this topic.…”
Section: Discussionmentioning
confidence: 99%
“…In some cases, a positive blood culture in a clinically well patient can lead to 6 weeks of intravenous antibiotic treatment and firm diagnosis, whereas in other situations absence of surgical re-intervention can negate a firm clinical and laboratory diagnosis previously made. The fact that manuscripts still appear regularly with new guidelines and criteria for endocarditis should caution us particularly when reviewing large retrospective cohort studies ( 22 , 23 ). There is slowly growing evidence that the bovine jugular graft, used in the surgically placed Contegra and percutaneously placed Melody valve (both Medtronic Inc., Minneapolis, MN) have an intrinsic proclivity to infection ( 24 , 25 ).…”
Section: Discussionmentioning
confidence: 99%
“…The sensitivity of Trans-esophageal Echocardiography (TEE) ranges between 85%-98%. In a study by Barbieri et al, a good quality TTE was found sufficient for diagnosis in 80% of cases with low level of clinical suspicion [28].…”
Section: Diagnosismentioning
confidence: 90%
“…The use TEE is necessary in cases where TTE is positive/non diagnostic, suspected complications (perforation, abscesses and fistula) or presence of intra-cardiac device leads [28,29]. ACC/AHA valvular heart guidelines recommended use of cardiac CT analysis when the anatomy is unclear following echocardiography [24].…”
Section: Diagnosismentioning