Estimation of whole-body skeletal muscle mass by bioelectrical impedance analysis in the standing position

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(22 citation statements)
references
References 16 publications
0
21
0
1
Order By: Relevance
“…The waist circumference was measured three times to the nearest 0.1 cm at the mid-point between the lower costal margin and the iliac crest using a calibrated measuring tape. A bioelectrical impedance measurement instrument (Karada Scan HBF354, 50 kHz, 500 mA; Omron Healthcare Co., Ltd., Kyoto, Japan) was used to measure body fat and muscle (Oshima et al, 2010). …”
Section: Exercise Programmentioning
confidence: 99%
“…The waist circumference was measured three times to the nearest 0.1 cm at the mid-point between the lower costal margin and the iliac crest using a calibrated measuring tape. A bioelectrical impedance measurement instrument (Karada Scan HBF354, 50 kHz, 500 mA; Omron Healthcare Co., Ltd., Kyoto, Japan) was used to measure body fat and muscle (Oshima et al, 2010). …”
Section: Exercise Programmentioning
confidence: 99%
“…Muscles consist of skeletal muscles, smooth muscles and cardiac muscles, and only skeletal muscles may be increased through exercise. When the skeletal muscle mass decreases, less energy is consumed, resulting in a reduced basal metabolism (19)(20)(21)(22)37). The present findings demonstrated that, in patients with pancreatobiliary cancer, there is little change in the skeletal muscle rate compared to the body fat rate.…”
Section: Discussionmentioning
confidence: 52%
“…At each visit for chemotherapy, the total weight (kg), body fat rate (%), skeletal muscle rate (%), body mass index (BMI), and basal metabolism of the subjects were measured as body composition parameters using a BI method-based body weight/body composition monitor (Karada Scan HBF-375; Omron Corporation, Kyoto, Japan). When using this measurement method, an electric microcurrent was applied with the patient in a standing position, between the hands and feet to the whole body, including the abdomen; measurements were obtained by subtracting the impedance value between both hands from the impedance value of the whole body (18,19). Following the acquisition of these values, the measurement was calculated by factoring in the height, weight, age, gender and basic physical data of the patients; Omron (http://www.omron.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Tanaka et al 40) reported that a segmental BIA can predict whole-body skeletal muscle volume more accurately than a whole-body BIA. Oshima et al 41) attempted to estimate the whole-body skeletal muscle mass by BIA in the standing position. The volume of the skeletal muscle obtained using MRI was made into a reasonable standard, and the measurement which deduces skeletal muscle volume simply was examined by using various kinds of anthropometric variables and impedance values or IPI (L 2 /Z) as an independent variable.…”
Section: Measurement Of Muscle Massmentioning
confidence: 99%