Recent Advances in Renewable Energy Technologies 2022
DOI: 10.1016/b978-0-12-823532-4.00004-5
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of solar irradiation and optimum tilt angles for south-facing surfaces in the United Arab Emirates: a case study using PVGIS and PVWatts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 51 publications
0
3
0
Order By: Relevance
“…Karinka and Upadhyaya 10 introduced a method to compute the OPT and they conclude that 12.0% of energy reduction if the tilt angle is not varied each month, which contradicts with the outcomes of this paper. Abdallah et al 11 made a comparison between SR of Horizontal Surface (HS) with that of the tilted surface which is varied each month with different 15%, which is less than the SR of this paper which is 24%. Xu et al 12 suggested a technique to compute the OTA on hilly places.…”
Section: Introductionmentioning
confidence: 70%
“…Karinka and Upadhyaya 10 introduced a method to compute the OPT and they conclude that 12.0% of energy reduction if the tilt angle is not varied each month, which contradicts with the outcomes of this paper. Abdallah et al 11 made a comparison between SR of Horizontal Surface (HS) with that of the tilted surface which is varied each month with different 15%, which is less than the SR of this paper which is 24%. Xu et al 12 suggested a technique to compute the OTA on hilly places.…”
Section: Introductionmentioning
confidence: 70%
“…In [10] a method was introduced to compute the OPT and they conclude that 12.0% of energy reduction if the tilt angle is not varied each month, which contradicts with the outcomes of this paper. In [11] a comparison between SR of Horizontal Surface (HS) with that of the tilted surface which is varied each month with different 15%, which is less than the SR of this paper which is 24%. Reference [12] suggests a technique to compute the OTA on hilly places.…”
Section: Introductionmentioning
confidence: 72%
“…The American Society of Heating, Refrigeration, and Air Conditioning Engineers model in [18] is adopted in this study to obtain IAM. The other losses are jointly considered by the PVWatts model developed by National Renewable Energy Laboratory [19]. For instance, soiling is regarded as 2%, and shading is regarded as 3%.…”
Section: Losses Modelmentioning
confidence: 99%