2020
DOI: 10.1038/s41598-020-58347-2
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of intracardiac shunts in young children with a novel indicator dilution technology

Abstract: clinical evaluation of intracardiac shunts in children is not straightforward. echocardiography can only diagnose the presence of a shunt but does not estimate the shunt ratio. this can be a critical factor that influences treatment options. In this single-center, prospective, observational, method-comparison study, we validate the ability of a novel monitoring device COstatus to estimate the intracardiac shunt ratio (Qp/Qs) of pulmonary (Qp) to systemic (Qs) blood flow in young children before and after corre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 34 publications
0
3
0
Order By: Relevance
“…Alternatively, this may also have been due to the difficulty of the program algorithm in exactly defining the right limits of the dilution curve, which was delayed in the presence of a shunt. 25 Our results raise a concern regarding the traditional way hae- under-represented in larger haemodynamic studies that therefore give an inaccurate overall picture. 1,30 In our opinion, the number of patients presented in this study was sufficient to give an overall view of haemodynamic values in these weight groups after heart surgery.…”
Section: Discussionmentioning
confidence: 80%
See 2 more Smart Citations
“…Alternatively, this may also have been due to the difficulty of the program algorithm in exactly defining the right limits of the dilution curve, which was delayed in the presence of a shunt. 25 Our results raise a concern regarding the traditional way hae- under-represented in larger haemodynamic studies that therefore give an inaccurate overall picture. 1,30 In our opinion, the number of patients presented in this study was sufficient to give an overall view of haemodynamic values in these weight groups after heart surgery.…”
Section: Discussionmentioning
confidence: 80%
“…Alternatively, this may also have been due to the difficulty of the program algorithm in exactly defining the right limits of the dilution curve, which was delayed in the presence of a shunt. 25 Our results raise a concern regarding the traditional way hae- under-represented in larger haemodynamic studies that therefore…”
Section: Discussionmentioning
confidence: 84%
See 1 more Smart Citation