2021
DOI: 10.1053/j.jvca.2020.07.067
|View full text |Cite
|
Sign up to set email alerts
|

To Swan or Not to Swan: Indications, Alternatives, and Future Directions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0
3

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 130 publications
0
9
0
3
Order By: Relevance
“…CO TPTD does not provide a continuous measurement and needs calibration after acute haemodynamic changes (Monnet and teboul, 2017;Rozental et al, 2021). However, the reproducibility of CO TPTD is higher (7% precision) than that of CO PTD (15% precision) (Giraud el al., 2017;Rozental et al, 2021).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…CO TPTD does not provide a continuous measurement and needs calibration after acute haemodynamic changes (Monnet and teboul, 2017;Rozental et al, 2021). However, the reproducibility of CO TPTD is higher (7% precision) than that of CO PTD (15% precision) (Giraud el al., 2017;Rozental et al, 2021).…”
Section: Discussionmentioning
confidence: 99%
“…CO TPTD does not provide a continuous measurement and needs calibration after acute haemodynamic changes (Monnet and teboul, 2017;Rozental et al, 2021). However, the reproducibility of CO TPTD is higher (7% precision) than that of CO PTD (15% precision) (Giraud el al., 2017;Rozental et al, 2021). The good reproducibility of transpulmonary thermodilution is related to the longer transit time of the thermal bolus (20 s), which reduces the artefacts produced by respiration, compared to pulmonary thermodilution (3-4 s).…”
Section: Discussionmentioning
confidence: 99%
“…The use of pulmonary artery catheter (PAC) has been the gold standard of cardiac output measurement for the last decades. Although its use in critical ill patients has been questioned heavily in the last years, PAC remains an effective means of monitoring RV performance in the perioperative setting [81]. It is still a frequently used monitoring tool in cardiac surgery [82].…”
Section: Comparison To Other Techniques Of Rv Function Assessmentmentioning
confidence: 99%
“…Se le ha atribuido desde una mayor mortalidad vinculado a su uso, hasta dificultades en su colocación e interpretación. No obstante y especialmente en cirugía cardíaca este sigue ocupando un lugar preponderante [19], dado que las medidas de la variables hemodinámicas (GC y resistencias sistémicas y pulmonares) han demostrado ser más fiables que las denominadas "no invasivas" y la medida de la SvO 2 y las derivadas del Co 2 han demostardo ser más confiables que aquellas obtenidas en la vena cava superior [20].…”
Section: Técnicas De Monitoreo De La Microcirculaciónunclassified