2015
DOI: 10.5424/fs/2015242-07580
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of Acacia melanoxylon unbleached Kraft pulp brightness by NIR spectroscopy

Abstract: Aim of the study: The ability of NIR spectroscopy for predicting the ISO brightness was studied on unbleached Kraft pulps of Acacia melanoxylon R. Br.Area of study: Sites covering littoral north, mid interior north and centre interior of Portugal. Materials and methods:The samples were Kraft pulped in standard identical conditions targeted to a kappa number of 15. A Near Infrared (NIR) partial least squares regression (PLSR) model was developed for the ISO brightness prediction using 75 pulp samples with a var… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 30 publications
(33 reference statements)
0
4
0
1
Order By: Relevance
“…First, the infrared data from the calibration samples were regressed against the measured fiber length and width, and by means of full cross-validation with one sample omitted a significant number of PLS components (rank) was obtained using OPUS/Quant 2 software (version 7.5.18 BRUKER, Bruker Corporation, Karlsruhe, Germany). Besides the raw spectra, also pre-processed spectra with 10 methods were used for PLS analysis [ 36 , 37 , 40 ]. In a second step, the validation of the PLS-R models was performed using the independent test set.…”
Section: Methodsmentioning
confidence: 99%
“…First, the infrared data from the calibration samples were regressed against the measured fiber length and width, and by means of full cross-validation with one sample omitted a significant number of PLS components (rank) was obtained using OPUS/Quant 2 software (version 7.5.18 BRUKER, Bruker Corporation, Karlsruhe, Germany). Besides the raw spectra, also pre-processed spectra with 10 methods were used for PLS analysis [ 36 , 37 , 40 ]. In a second step, the validation of the PLS-R models was performed using the independent test set.…”
Section: Methodsmentioning
confidence: 99%
“…These measurements, although simple, must be done carefully in order to avoid non-sampling errors (Soares et al, 2011), which can impact the analysis when one or more values are out of the general trend of the data and are considered as outliers. Because of their marked difference, according to Santos et al (2015), the number of outliers should be as low as possible. There are several ways to identify them, among which stands out the boxplot graphic (Schwertman et al, 2004).…”
Section: Introductionmentioning
confidence: 99%
“…A espectroscopia na região do infravermelho próximo (NIR) tem sido frequentemente aplicada como método analítico que fornece resultados eficientes para a determinação de moléculas orgânicas e variáveis quantitativas. A ferramenta NIR está presente em quase todas as áreas do conhecimento, devido ao nível de desenvolvimento de tecnologia, principalmente nos setores agrícola, alimentício, têxtil, cosméticos de polímeros, petroquímica, farmacêutica, ambiental e florestal (LEBLON et al, 2013;MUÑIZ et al, 2013;SANTOS et al, 2015).…”
Section: Introductionunclassified