2020
DOI: 10.1016/j.radonc.2020.05.014
|View full text |Cite
|
Sign up to set email alerts
|

Estimating dose delivery accuracy in stereotactic body radiation therapy: A review of in-vivo measurement methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
36
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 41 publications
(37 citation statements)
references
References 112 publications
0
36
0
Order By: Relevance
“…In order to prevent future misinterpretations, a concise definition of IVD in the scope of EBRT is provided in the Methods section. According to this definition, point detectors placed on the patient's skin in the treatment field such as thermoluminescent detectors, silicon diodes, metal-oxide semiconductor field-effect transistors, optically stimulated luminescence dosimeters, and electronic portal imaging devices (EPIDs) [4,5] are the main commercially available IVD methods. Due to the limitations of point detectors for large-scale implementation of IVD in modern EBRT, the emphasis of this report lies on EPID-based IVD (EIVD) systems.…”
Section: Introductionmentioning
confidence: 99%
“…In order to prevent future misinterpretations, a concise definition of IVD in the scope of EBRT is provided in the Methods section. According to this definition, point detectors placed on the patient's skin in the treatment field such as thermoluminescent detectors, silicon diodes, metal-oxide semiconductor field-effect transistors, optically stimulated luminescence dosimeters, and electronic portal imaging devices (EPIDs) [4,5] are the main commercially available IVD methods. Due to the limitations of point detectors for large-scale implementation of IVD in modern EBRT, the emphasis of this report lies on EPID-based IVD (EIVD) systems.…”
Section: Introductionmentioning
confidence: 99%
“…Esposito et al 20 performed the IQM that is a useful in vivo dosimetry tool with the strengths of real-time monitoring of linac status and can monitor all fractions. The differences in surface and build-up dose, PDD 20,10 , PDD curves, and crossline/inline profiles, and attenuation of the IQM for 6-and 10-MV X-ray beams with and without the IQM were relatively similar to the findings published in previous papers.…”
Section: C | the Effect Of Iqm On The Crossline And Inline Profilesmentioning
confidence: 99%
“…[9][10][11][12][13][14][15][16][17][18][19] The point dosimeters and EPID are sensitive to linac and patient errors. 20 Transmission detectors monitor linac performance with high sensitivity in real time. 20 Linac log file analysis is sensitive to plan corruption errors.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations