1995
DOI: 10.1063/1.1146167
|View full text |Cite
|
Sign up to set email alerts
|

ESCA microscopy beamline at ELETTRA

Abstract: Angle-resolved environmental X-ray photoelectron spectroscopy: A new laboratory setup for photoemission studies at pressures up to 0.4 Torr Rev. Sci. Instrum. 83, 093112 (2012) A new double imaging velocity focusing coincidence experiment: i2PEPICO Rev. Sci. Instrum. 83, 083105 (2012) Gamma-to-electron magnetic spectrometer (GEMS): An energy-resolved γ-ray diagnostic for the National Ignition Facility Rev. Sci. Instrum. 83, 10D311 (2012) Magnetic pulser and sample holder for time-and spin-resolved photoemis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

1997
1997
2012
2012

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 76 publications
(24 citation statements)
references
References 13 publications
0
24
0
Order By: Relevance
“…More technical details about the beamline are published in Ref. [8]. Electron energy distribution curves (EDC) were measured by means of a hemispherical analyser (angle of emissionx 19') operated in the constant energyresolution mode (overall working energy resolution M 0.44 eV ) .…”
Section: Methodsmentioning
confidence: 99%
“…More technical details about the beamline are published in Ref. [8]. Electron energy distribution curves (EDC) were measured by means of a hemispherical analyser (angle of emissionx 19') operated in the constant energyresolution mode (overall working energy resolution M 0.44 eV ) .…”
Section: Methodsmentioning
confidence: 99%
“…This ultra-high vacuum (UHV) setup [19][20][21] enables X-ray photoemission spectroscopy (XPS) measurements with high spatial resolution. This is achieved by refractive focusing of the incoming photon beam by means of a Fresnel zone plate, down to a focal spot size with a diameter of about 150 nm.…”
Section: Spectro-microscopy the Investigation Of Si Andmentioning
confidence: 99%
“…The working distance is about half the focal length, because an order sorting aperture should be placed between the zone plate and the sample. 1,3,7 The relationship between the focal length f, zone plate parameters (diameter D and outer zone width dr) and photon energy E (eV) are described by…”
Section: Imaging and Resolution In Transmission And Photoemission : Tmentioning
confidence: 99%
“…7. From the 20È80% rise in the intensity across the knife edge, a spatial resolution of 150 nm was measured for a zone plate with a theoretical resolution of 122 nm.…”
Section: Imaging and Resolution In Transmission And Photoemission : Tmentioning
confidence: 99%