2004
DOI: 10.1016/j.tca.2004.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Erratum to “Influence of thermal treatment on the ion-storage capacity of Ce oxide and Ce–V mixed oxide films” [Thermochim. Acta 411 (2004) 211–217]

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…155 Korosec et al realized NiO x thin lms using Ni-acetate as the precursor. 156 During the decomposition of the precursor at 250 C the formation of nano-sized NiO x took place. Ryu et al have used this approach to modify the surface of graphene oxide by wet-chemical deposition of NiO x at somewhat higher (280 C) decomposition temperature for use in OSCs.…”
Section: Materials and Chemistrymentioning
confidence: 99%
“…155 Korosec et al realized NiO x thin lms using Ni-acetate as the precursor. 156 During the decomposition of the precursor at 250 C the formation of nano-sized NiO x took place. Ryu et al have used this approach to modify the surface of graphene oxide by wet-chemical deposition of NiO x at somewhat higher (280 C) decomposition temperature for use in OSCs.…”
Section: Materials and Chemistrymentioning
confidence: 99%
“…129.6(3) The first mass loss was observed up to 150 °C probably is due to loss of coordinated one molecule of water. Second mass loss observed between 160-260 °C that indicating the coordinated acetate group [25]. Thus the thermogravimetric curve of the Figure 4 indicate that thermal properties of Zn(II) complex is completely approving its thermal stability.…”
Section: Thermogravimetric Analysis (Tga)mentioning
confidence: 78%
“…More mass loss was observed for the CePO 4 /SiC precursor, which can be attributed to the mass loss of the CePO 4 precursor. Combined with the DTA curves (Figure S2b), it was found that the SiC membrane and CePO 4 /SiC precursor had broad heat absorption peaks at 25–550 °C, which might be attributed to the evaporation of water and the removal of hydroxyl groups. , To further analyze the mass loss of the CePO 4 catalyst precursor, TG-DTA test (Figure S3a) were subsequently performed on CePO 4 precursor powders that were dried at 120 °C. The TG curve show that the CePO 4 precursor powders experienced a 20% mass loss from 50 to 750 °C.…”
Section: Resultsmentioning
confidence: 99%