2015
DOI: 10.1007/978-3-319-14929-5_20
|View full text |Cite
|
Sign up to set email alerts
|

Errata to: Advanced Time-Correlated Single Photon Counting Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
114
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 72 publications
(114 citation statements)
references
References 0 publications
0
114
0
Order By: Relevance
“…Different from intensity-based imaging, molecular lifetime is a relatively stable parameter in certain ambient environments, and can elude effects of dye concentration, heterogeneous distribution, and light scattering in tissue. This relatively 'intrinsic' property of lifetime imaging makes it a strong candidate for imaging tissue oxygen condition, and is considered sufficiently sensitive to produce high-contrast spatial heterogeneous information of tissue oxygenation [39,40]. In addition, quenching method is a reversible way, in which the upper state lifetime or the luminescence intensity of the oxygen-sensitive dye is reduced with high oxygen concentration, but can be recovered with low oxygen concentration.…”
Section: Photoacoustic Imaging In Po 2 Measurementmentioning
confidence: 99%
“…Different from intensity-based imaging, molecular lifetime is a relatively stable parameter in certain ambient environments, and can elude effects of dye concentration, heterogeneous distribution, and light scattering in tissue. This relatively 'intrinsic' property of lifetime imaging makes it a strong candidate for imaging tissue oxygen condition, and is considered sufficiently sensitive to produce high-contrast spatial heterogeneous information of tissue oxygenation [39,40]. In addition, quenching method is a reversible way, in which the upper state lifetime or the luminescence intensity of the oxygen-sensitive dye is reduced with high oxygen concentration, but can be recovered with low oxygen concentration.…”
Section: Photoacoustic Imaging In Po 2 Measurementmentioning
confidence: 99%
“…FRET between eGFP‐ and mCherry‐labeled proteins only occurs when they are less than 8 nm apart, a distance corresponding to intermolecular protein interactions . The FRET efficiency is ideally measured through the decrease of the fluorescence lifetime of eGFP by fluorescence lifetime imaging microscopy (FLIM) …”
Section: Resultsmentioning
confidence: 99%
“…99,161,162 Similar to previous components, also in this case, the main impairments are high cost, high power dissipation, and limited performance (e.g., conversion time, linearity, time resolution, and so on). After that, a final stage provides a digital number that encodes such time with respect to the synchronization signal.…”
Section: Timing Electronicsmentioning
confidence: 96%