Erosion and deposition investigations on Wendelstein 7-X first wall components for the first operation phase in divertor configuration

Abstract: In the stellarator Wendelstein 7-X with its twisted 3D magnetic field geometry, studies of material migration with respect to first wall components become very important in view of the envisioned long-pulse operation. A variety of erosion/deposition samples were installed on the plasma-facing components exposed at three different nominal heat load levels between 0.1 and 10 MW/m 2. After the first successful operation phase in divertor configuration, all the probes at higher and lower load levels were removed, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 7 publications
1
11
0
Order By: Relevance
“…2.5 MeV incident protons at normal incidence and a scattering angle of 165° were used, see Figs. 1 and 2 in [15] for typical spectra. A passivated implanted planar silicon (PIPS) detector with a thickness of 300 μm and nominal energy resolution of about 12 keV was used.…”
Section: Analysis Of the Marker Layersmentioning
confidence: 99%
“…2.5 MeV incident protons at normal incidence and a scattering angle of 165° were used, see Figs. 1 and 2 in [15] for typical spectra. A passivated implanted planar silicon (PIPS) detector with a thickness of 300 μm and nominal energy resolution of about 12 keV was used.…”
Section: Analysis Of the Marker Layersmentioning
confidence: 99%
“…© 2019 EURATOM. [9]. In section 3, the impact of boronisation on the impurity influx into the confined plasma [10] as well as the oxygen (O) gettering in deposited boron (B) layers is discussed.…”
Section: Introductionmentioning
confidence: 99%
“…A Passivated Implanted Planar Silicon (PIPS) detector with 300 µm thickness and about 12 keV nominal energy resolution was used [5]. Nuclear Reaction Analysis (NRA) was carried out with incident 2.5 MeV 3He ions using the 12 C( 3 He,p0) 14 N and 10 B( 3 He,p1) 12 C reactions. The experimental spectra were evaluated using the software SIMNRA [6].…”
Section: Methodsmentioning
confidence: 99%
“…Forty-four pieces of long term deposition probes of three different types, i.e. Si-wafer, directional material and cavity probes [13,14] were installed at the outboard wall as well as at the pumping gap panels in module 4 (see fig. 1) for monitoring depositions on these low power loaded components.…”
Section: Wafer Probe Holdermentioning
confidence: 99%