2000
DOI: 10.1002/1521-4109(200011)12:16<1312::aid-elan1312>3.0.co;2-l
|View full text |Cite
|
Sign up to set email alerts
|

Epoxy Matrix Membrane Potentiometric Sensor Based on Zirconium Titanium Phosphate Ion Exchanger for Flow Injection Analysis of Nitrite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2002
2002
2009
2009

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…The potentiometric selectivity coefficients (K pot SCN,J) of thiocyanate sensors based on the Cu-PADAP complex in a PVC membrane plasticized with o-nitrophenyloctyl ether (o-NPOE) with and without anionic and cationic additives were evaluated using the separate solutions method, 36,37 with EMF values measured in 0.1 M salt solutions and theoretical slope values. Although, the calibration slopes of most interfering ions measured with anionic additive containing membranes were sub-Nernstian, the theoretical slope values were used instead for calculating their selectivity coefficients.…”
Section: Potentiometric Characteristics Of Thiocyanate Membrane Sensorsmentioning
confidence: 99%
“…The potentiometric selectivity coefficients (K pot SCN,J) of thiocyanate sensors based on the Cu-PADAP complex in a PVC membrane plasticized with o-nitrophenyloctyl ether (o-NPOE) with and without anionic and cationic additives were evaluated using the separate solutions method, 36,37 with EMF values measured in 0.1 M salt solutions and theoretical slope values. Although, the calibration slopes of most interfering ions measured with anionic additive containing membranes were sub-Nernstian, the theoretical slope values were used instead for calculating their selectivity coefficients.…”
Section: Potentiometric Characteristics Of Thiocyanate Membrane Sensorsmentioning
confidence: 99%
“…[24][25][26] Logarithm Hg 2+ concentrations (log aHg) and the interfering ions (B) vs. sensor response (E) was independently obtained. The intersection of the extrapolated linear portions of this plot indicated the value of the concentration of interfering ion (aB).…”
Section: Sensor Selectivitymentioning
confidence: 99%
“…Exploiting the volatility of acidified nitrite (yielding nitrous acid, HNO 2 ) through micro-distillation and the subsequent potentiometric detection has proven to provide both improved sensitivity (LOD: 5 mg L 21 , 0.1 mM) and selectivity. 59 Interference from sulfite and sulfide was noted and can be ascribed to the volatility of their acidified forms (H 2 S, SO 2 ). Care would clearly need to be taken when considering the applicability of the approach to industrial samples where these species are liable to be present at significant levels (effluent discharge from paper processing/tanneries etc).…”
Section: Electrochemical Detectionmentioning
confidence: 99%